background image

 

14 

 

 

 

To lock the housing: 

 

 

 

 

1.

 

Close  the  housing  while  the 
housing is in the “Open” position.

 

2.

 

Turn the housing lock clockwise 
for  270°,  until  the  lock  reaches 
the  “lock”  position  as  shown.  
Confirm 

that 

the 

white 

indicator  line  on  the  safety 
button is visible. 

Содержание NA-G7XIII

Страница 1: ...1 ...

Страница 2: ... of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camera Each housing is individually inspected and water pressure tested to ensure optimum quality Please read this manual carefully before using the housing this will maximize its performance as well as its lifetime The illustrations in t...

Страница 3: ... Package Contents 7 Specifications 8 Identification of Parts 9 Opening and Locking the Housing 13 Preparation of the Housing 15 Installing the Camera 20 Changing the Port 21 Connecting HDMI Cable 23 Care and Maintenance 24 Optional Accessories 25 ...

Страница 4: ... authorized service center s Please note that this warranty only applies when the product is purchased in the territory where the service center is located NAUTICAM accepts no liability for any damage to and defects in the housing caused by improper use and or poor maintenance it is the responsibility of the owner to carefully follow the instructions in our manuals NAUTICAM does not hold responsib...

Страница 5: ...nt provided by NAUTICAM Discontinue use immediately should you notice any leakage Store the housing in a robust shock proof container during transportation avoid transporting with any equipment such as a camera inside the housing When travelling by air do not close the housing as this may lead to a pressure difference between the atmosphere and inside the housing Care must be taken when opening th...

Страница 6: ...unlight for prolonged periods Keep out of reach of children failure to do so could result in injury Defective products should be shipped to our distributors for service unauthorized disassembling and or modifications could result in malfunction or leakage Use only recommended battery with this product do not mix different specifications or old and new batteries Do not place excessive stress on you...

Страница 7: ...lve Vacuum Pump Shoulder Strap NA G7XIII Housing N50 Standard Port with Cap 2x Handles Brackets 2x Optical Bulkhead Plugs Shutter Release Extension 90135 Spare Silicone Rubber O ring for Housing O ring Remover CR2032 Battery Lubricant Set of Allen Keys Manual Instruction Card Padded Travel Bag ...

Страница 8: ...eatment Hard anodized Display window Abrasion resistant polycarbonate Dimensions Width 155mm w o handles Height 103mm Depth 111mm Weight in air Approx 0 95kg Weight in water 0 05kg Depth rating 100 m Port mount N50 Compatible cameras Canon PowerShot G7X Mark III Camera ...

Страница 9: ...9 IDENTIFICATION OF PARTS Shutter Release Lever Front Control Wheel N50 Standard Port Port Release Safety Button Optical Fiber Mount Handle brackets and Shutter release extension are not displayed ...

Страница 10: ...Off Button Moisture Alarm Window M16 Accessory Port M14 Accessory Port Exposure Dial Zoom Lever Lock Accessory Coldshoe M10 Strobe Mounting Base Port Alignment Index Handle brackets and Shutter release extension are not displayed ...

Страница 11: ...ash Up Off Lever Housing Lock Housing Lock Safety Button M16 Accessory Port Threaded Holes for Handle Brackets Attachment Point for Hand Strap Handle brackets and Shutter release extension are not displayed ...

Страница 12: ...Mounting Holes for LCD Magnifier Attachment Rails Movie Button Control Wheel Playback Button Left MF Button Erase Button Up Drive Mode Button Set FUNC Button Right Flash Button Down INFO Button Menu Button ...

Страница 13: ...13 OPENING AND LOCKING THE HOUSING To open the housing 1 Press the housing lock safety button 2 Turn the housing lock anti clockwise for 270 until the lock reaches the Open position as shown ...

Страница 14: ... 1 Close the housing while the housing is in the Open position 2 Turn the housing lock clockwise for 270 until the lock reaches the lock position as shown Confirm that the white indicator line on the safety button is visible ...

Страница 15: ... any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the main O ring into the groove first at the corners then the whole perimeter 4 Setting up the moisture alarm 1 Ensure removal of the insulation film before installing a battery Then install the battery provided into the battery compartment on the circuit board inside the housing PREPARATION OF THE HOUSING ...

Страница 16: ...stallation Use only recommended battery with this product Insert the battery as shown above and then press down the battery Press To remove the battery press the metal plate as indicated and the battery will pop out Press ...

Страница 17: ...oes into flashing blue light standby mode 3 Test the alarm by connecting the two wires near the bottom of the housing with a damp cotton bud the alarm should start giving out a repeating beep sound along with a flashing red light The beep sound and the light should keep on going for 5 seconds after the removal of the damp cotton bud ...

Страница 18: ...s of the operation LED status identification On start up LED indicator Status Flash Blue light once Indicates a 2nd generation PCB Steady Blue light Battery is normal goes into flashing Blue light standby mode after 5 seconds Blue and Red lights alternating Battery low Replace battery as soon as possible Goes into standby mode after 5 seconds Steady Red light Battery empty replace battery ...

Страница 19: ...oisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reached Steady Green light Target vacuum level is reached Rapidly flash Yellow light Vacuum is dropping Will occur only after target vacuum level is reached Rapidly flashing Red light Vacuum is totally lost Circuit stalled until switched off Will occur only after target vacuum level is reached After start ...

Страница 20: ...using as shown Due to space limitation the pop up flash needs to be in up position before connecting with the internal HDMI cable Flash up lever is disabled when using an external monitor 2 Confirm that all the controls of the housing are correctly engaged INSTALLING THE CAMERA ...

Страница 21: ...yonet Mount To use with WWL 1 To avoid the camera lock up and power down please set the recommended zoom range 24mm 50mm to use with 38701 N50 Short Port with M67 thread for WWL 1 or 38703 N50 Short Port with Bayonet Mount To remove Port CHANGING THE PORT 1 Press and hold the red port lock safety button to unlock 2 While holding the red port lock safety button turn the port counter clockwise until...

Страница 22: ...gn the I mark on the port with the o mark on the housing 4 Gently push the port towards the housing until it cannot go any further 5 Turn the port clockwise until the o mark on the port aligns with the o mark on the housing ...

Страница 23: ...Extension and 25032 Custom HDMI bulkhead the NA NA G7XIII is compatible with external monitor housings such as the NA 502B H or NA Ninja V HDMI 1 4 connection only The socket extension will be provided for free to use with external monitor housings under request ...

Страница 24: ... with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp object The O ring groove should be cleaned to ensure it is free from any salt deposit or foreign material lightly coat the O ring with the provided lubricant before reinstalling it in the groove A damaged O ring should be di...

Страница 25: ...s for NA S110 S120 TG3 G7X G7XII TG5 G7XIII P N 38022 Diffuser for NA G7X G7XII G7XIII housing OPTIONAL ACCESSORIES P N 25106 LCD Magnifier with Dioptric Adjustment P N 38703 N50 Short Port with Bayonet Mount To use with WWL 1 zoom range 24 65mm P N 38702 N50 3 5 Acrylic Wide Angle Dome Port ...

Страница 26: ... N 71206 Easitray II with left handle with 2pcs screws P N 71207 Flexitray II with left handle with 2pcs screws P N 71208 Adjustable right handle II for Easitray II Flexitray II P N 83201 Wet Wide Lens 1 WWL 1 130 deg FOV with compatible 28mm Lenses ...

Страница 27: ...t Macro Convertor 2 CMC 2 2 8X Magnification P N 17906 17907 NA 502H housing for Small HD 502 5 inch HD monitor with HDMI 1 4 input support P N 17920 17921 NA 502B H Housing for SmallHD 502 Bright Monitor with HDMI 1 4 input support All the needed cables and bulkhead are included in the monitor housing ...

Страница 28: ...6 HDMI D D Cable in 200mm Length for NA XT2 XH1 A6400 for internal connection from HDMI bulkhead to camera P N 25028 Socket extension for 25032 HDMI bulkhead with M16 thread P N 25032 Custom HDMI bulkhead to use with socket extension ...

Страница 29: ...29 ...

Отзывы: