16 

 

5.

 

Gently push the ON/OFF lever 
downwards ensuring the 
actuator correctly engages 
with the ON/OFF lever of the 
camera.

 

 

6.

 

Gently push the mode dial 
downwards until it cannot go 
any further. 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

 

Confirm that all the controls of 
the housing are correctly 
engaged. 

8.

 

For removal of the camera from    
the housing, reverse the above   
procedures. 

Содержание NA-EM10II

Страница 1: ...0...

Страница 2: ...m through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camera...

Страница 3: ...To return your product for service please contact your regional authorized service centre s Please note that this warranty only applies when the product is purchased in the territory where the service...

Страница 4: ...4 O ring remover 5 CR2032 battery for moisture alarm 6 Lubricant 7 Set of Allen keys 8 Pair of handle brackets 9 Shutter release extension Spare silicone rubber o ring Lubricant Pair of handle bracke...

Страница 5: ...g if the port is installed as this may lead to a pressure difference between the atmosphere and inside the housing 6 Care must be taken when opening the housing as pressure may build up inside the hou...

Страница 6: ...s 6 Identification of Parts 7 Preparation of the Housing 10 Opening and Locking the Housing 14 Installing the Camera 15 Mounting the Port 17 Changing the Viewfinder 19 Care and Maintenance 20 Optional...

Страница 7: ...ating 100 metres Features Moisture alarm Blinking LED and audible alarm TTL capability Optical fibre mount included for external strobes connection utilising the camera s pop up flash as trigger Port...

Страница 8: ...dial 6 Housing lock safety button 2 Rear dial 7 Housing lock 3 Fn2 button 8 M10 strobe mounting base 4 Movie lever 9 Front dial 5 Threaded holes for handle brackets 10 Shutter release lever 3 7 8 9 1...

Страница 9: ...alignment index 19 Zoom Focus knob 14 M14 accessory port 20 Port release safety button 15 Lens release button 21 Port lock release lever 16 ON OFF Flash up lever 22 1 4 20UNC tripod socket x 2 11 12...

Страница 10: ...t selection button 23 LV lever 29 Right selection button 24 Fn1 button 30 OK button 25 Menu button 31 Down selection button 26 INFO button 32 Playback button 27 Up selection button 33 Erase button 25...

Страница 11: ...ove located in the rear part of the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the O ring into the groove 4 To install the optical f...

Страница 12: ...near the bottom of the housing with a damped cotton bud the alarm should start giving out a repeating beep sound along with a flashing red light The beep sound and the light should keep on going for...

Страница 13: ...m is ready for vacuum indication whenever a vacuum is detected Flashing Red light with audio sounds Moisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reache...

Страница 14: ...function of the EM10II camera to Off allows switching between monitor display and EVF display by pressing the LV button To disable this function press and hold the LV button for a few seconds the EVF...

Страница 15: ...reaches the Open position as shown 3 Close the housing while the housing lock is in the Open position 4 Turn the housing lock clockwise for 270 until the lock reaches the lock position as shown Confi...

Страница 16: ...ing it outwards 2 Tilt the LCD monitor of the camera upwards then attach the saddle to the camera by tightening the screw to the tripod socket of the camera 3 Lift the ON OFF lever and Mode dial upwar...

Страница 17: ...correctly engages with the ON OFF lever of the camera 6 Gently push the mode dial downwards until it cannot go any further 7 Confirm that all the controls of the housing are correctly engaged 8 For re...

Страница 18: ...any damage and lightly coat it with the provided lubricant before placing it back into its groove 2 Verify that the port opening of the housing is clean and free from foreign material 3 Push the safe...

Страница 19: ...any further 8 Lock the port into place by turning the port locking lever to the inward position To ensure that the port is securely mounted confirm that the green line on the safety button of the por...

Страница 20: ...housing is designed so that it can be removed and re installed by following the simple steps described below 2 Gently push the viewfinder from the inside of the housing 1 Lightly coat the O rings on...

Страница 21: ...damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp object The O ring groove should be cleaned to ensure it is free fro...

Страница 22: ...21 P N 25611 M14 Vacuum Valve P N 32204 Nauticam 180 straight viewfinder for MIL housings P N 32205 Nauticam 45 viewfinder for MIL housings...

Страница 23: ...22...

Отзывы: