1.

 

Soak the housing system in fresh water after each salt water use, during which 
all control buttons/knobs should be operated a few times to avoid the 
accumulation of salt residue; wipe the housing with a towel before opening. 

2.

 

Carefully press the port locking safety button and the two housing lock safety 
buttons for a few times to avoid the accumulation of salt residue. Hold the 
port lock in "locked" position while pressing the safety buttons. 

 

 

 

 

 

 

 

 

   

3.

 

After each day of diving, it is advisable to have the main O-ring in the front part 
of the housing removed from its groove with the O-ring remover and 
inspected for damage.  Also check that the O-ring retains its original circular 
shape; never stretch the O-ring excessively or remove it with a sharp object.  
The O-ring groove should be cleaned to ensure it is free from any salt deposit 
or foreign material; lightly coat the O-ring with the provided lubricant before 
reinstalling it in the groove.  A damaged O-ring should be discarded 
immediately and replaced only with one that is provided by NAUTICAM. 

4.

 

Replace the main O-ring annually. 

5.

 

It is recommended that you ship the housing to our distributor for a complete 
overhaul every year or after every 200 dives. 

Содержание NA-A7

Страница 1: ...0...

Страница 2: ...them through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the ca...

Страница 3: ...hin the housing 4 NAUTICAM accepts no liability for any loss of captured images or the inability to capture images even if it is due to the malfunctioning or leakage of the housing 5 This warranty onl...

Страница 4: ...g 4 O ring remover 5 CR2450 battery for moisture alarm 6 Lubricant 7 Set of Allen keys 8 M10 plastic plug removal tool 9 M16 plug 10 Universal hotshoe plug Spare silicone rubber o ring Lubricant Set o...

Страница 5: ...g if the port is installed as this may lead to a pressure difference between the atmosphere and inside the housing 6 Care must be taken when opening the housing as pressure may build up inside the hou...

Страница 6: ...pecifications 6 Identification of Parts 7 Opening and Closing the Housing 10 Preparation of the Housing 11 Installing the Camera 15 Mounting the Port 17 Changing the Viewfinder 19 Care and Maintenance...

Страница 7: ...ra Buoyancy Slightly negative Depth rating 100 metres Features Moisture alarm Blinking LED and audible alarm Viewfinder 0 66X viewfinder Flash capability One Nikonos 5 pin bulkhead Trigger and Ground...

Страница 8: ...Port lock release lever 7 Lens release button 3 Optical bulkhead for strobe connections x 2 8 M14 optional accessory port 4 Port alignment index 9 Playback lever 5 Nikonos 5 pin bulkhead with M16 to M...

Страница 9: ...re alarm window 13 Housing lock L 21 Display Up selection button 14 C2 Enlarge button 22 Drive mode Left selection button 15 AF MF AEL switch lever 23 Set button 16 Fn button 24 White Balance Right se...

Страница 10: ...9 26 Exposure compensation dial 31 On off lever 27 Rear dial 32 C1 button 28 Movie lever 33 Shutter release lever 29 AF MF AEL lever 34 Front dial 30 Mode dial 27 31 29 26 30 28 32 33 34...

Страница 11: ...ke sure there is nothing caught between the closing surfaces of the two halves of the housing 3 The housing can be opened and closed by operating the two housing locks when opening press the safety bu...

Страница 12: ...bricant provided 2 Make sure the O ring groove located in the front part of the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the main...

Страница 13: ...larm The LED light will turn blue for five seconds indicating the battery is normal Then it goes into flashing blue light standby mode 3 Test the alarm by contacting the two wires near the bottom of t...

Страница 14: ...ation whenever a vacuum is detected Flashing Red light with beeping sound Moisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reached Steady Green light Targe...

Страница 15: ...amera saddle lock by pressing it inwards Remove the camera saddle from the housing by sliding it outwards 4 Confirm that all the controls of the housing are correctly engaged 5 For removal of the came...

Страница 16: ...tible ports note that extension rings may be needed for certain lenses and adaptors are available for the attachment of ports of other manufacturers 1 Push the safety button of the port locking lever...

Страница 17: ...m that the green line on the safety button of the port locking lever is visible 10 To remove the port from the housing simply turn the port locking lever to the outward position and gently pull it out...

Страница 18: ...d re installed by following the simple steps described below To remove the viewfinder To re install the viewfinder 3 Push the viewfinder from the outside of the housing until it cannot go in any furth...

Страница 19: ...ain O ring in the front part of the housing removed from its groove with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O...

Страница 20: ...19...

Отзывы: