background image

Connect 

23 

 

C

ONNECTING TO THE 

C

AMERA 

H

OUSING

 

 

For installing the standard HDMI bulkhead with M16 thread or M16 SDI bulkhead: 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

Unscrew  the  M16  plug  from  the 

threaded hole with a coin. 

2.

 

Tighten  the  HDMI  or  HD-SDI 
bulkhead with a spanner. 

Содержание 17909

Страница 1: ...1...

Страница 2: ...em through the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camer...

Страница 3: ...6 Specifications 8 Identification of Parts 9 Opening and Locking the Housing 13 Preparation of the Housing 15 Installing the Monitor 21 Connecting to the Camera Housing 23 Optional SDI Output to Surfa...

Страница 4: ...contact your regional authorized service center s Please note that this warranty only applies when the product is purchased in the territory where the service center is located NAUTICAM accepts no lia...

Страница 5: ...5046 HDMI D D cable in 200mm length for connection from HDMI bulkhead to camera 4 25071 HDMI Cable A D in 0 75m length for connection from Shogun housing to HDMI bulkhead Pre installed For 17910 Nauti...

Страница 6: ...nt provided by NAUTICAM Discontinue use immediately should you notice any leakage Store the housing in a robust shock proof container during transportation avoid transporting with any equipment such a...

Страница 7: ...nlight for prolonged periods Keep out of reach of children failure to do so could result in injury Defective products should be shipped to our distributors for service unauthorized disassembling and o...

Страница 8: ...909N Weight in Water 0 4Kg 17909 and 17910 0 52kg 17909N Depth rating 60 m Compatible monitor 1 17909 Atomos Ninja Flame Shogun Flame Ninja Inferno Shogun Inferno 7 10 bit 4K HD SDI HDMI Recorder Moni...

Страница 9: ...9 REC Button PLAY Button WF Button MON Button Multi Selector Lever IDENTIFICATION OF PARTS...

Страница 10: ...10 Moisture Alarm Window M16 Accessory Port Attaching Point for Mounting Ball M16 Vacuum Valve II Fan LED Window HDMI or SDI cable 17909N includes M28 Accessory Port...

Страница 11: ...11 Monitor ON OFF FAN ON OFF Housing Lock Safety Button Cable Cap 17909N doesn t include a cable...

Страница 12: ...12 Attaching Point for Mounting Ball Sacrificial zinc anode...

Страница 13: ...13 OPENING AND LOCKING THE HOUSING To open the housing 1 Press the housing lock safety button 2 Turn the housing lock 270 counter clockwise until the lock reaches the Open position as shown...

Страница 14: ...Close the housing while the housing lock is in the Open position 4 Turn the housing lock 270 clockwise until the lock reaches the lock position as shown Confirm that the white indicator line on the s...

Страница 15: ...the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the main O ring into the groove first at the corners then the whole perimeter 4 Setti...

Страница 16: ...lation Use only recommended battery with this product Insert the battery as shown above and then press down the battery Press To remove the battery press the metal plate as indicated and the battery w...

Страница 17: ...es into flashing blue light standby mode 3 Test the alarm by connecting the two wires near the bottom of the housing with a damp cotton bud the alarm should start giving out a repeating beep sound alo...

Страница 18: ...D status identification On start up LED indicator Status Flash Blue light once Indicates a 2nd generation PCB Steady Blue light Battery is normal goes into flashing Blue light standby mode after 5 sec...

Страница 19: ...isture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reached Steady Green light Target vacuum level is reached Rapidly flash Yellow light Vacuum is dropping Will...

Страница 20: ...20 5 Setting up fans 1 Then install Sony NP F570 battery into the battery compartment on the housing 2 To remove the battery press the square button as indicated...

Страница 21: ...stall the monitor into to the housing 1 Turn the three locking levers in the direction as shown 2 Connect the HDMI cable with L connector to the monitor s HDMI IN socket as shown above or HD SDI cable...

Страница 22: ...22 3 Place the monitor inside the housing and secure the monitor by turning the three locking levers towards the monitor as shown...

Страница 23: ...CTING TO THE CAMERA HOUSING For installing the standard HDMI bulkhead with M16 thread or M16 SDI bulkhead 1 Unscrew the M16 plug from the threaded hole with a coin 2 Tighten the HDMI or HD SDI bulkhea...

Страница 24: ...24 3 Connect the HDMI HD SDI cable to the HDMI HD SDI bulkhead 4 Connect the HDMI HD SDI cable to the camera s HDMI HD SDI socket...

Страница 25: ...25 For installing the custom HDMI bulkhead to use with extension 1 Unscrew the M16 plug from the accessory port with a coin 2 Tighten the socket extension to the camera housing with a spanner...

Страница 26: ...Tighten the HDMI bulkhead by turning the threaded ring on the socket extension 3 Insert the HDMI cable through the threaded hole from inside of the housing and connect the HDMI cable to the HDMI bulk...

Страница 27: ...27 5 Connect the HDMI cable to the camera s HDMI connector...

Страница 28: ...I bulkhead 1 Unscrew the cap off the HDMI SDI bulkhead 2 Unscrew the cap off the HDMI HD SDI cable and Align and plug the HDMI HD SDI cable in the HDMI HD SDI bulkhead Tighten the connection by turnin...

Страница 29: ...the monitor SDI IN socket 1 Attach and Tighten the M16 SDI bulkhead with a spanner on the housing OPTIONAL SDI OUTPUT TO SURFACE MONITOR Nauticam Atomos Flame Housing with SDI input features SDI Pass...

Страница 30: ...with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp object The O ring groove...

Страница 31: ...gun Flame on Epic LT Housing P N 17919 Monitor Hood for Nauticam Atomos Shogun Flame Housing Mounting System P N 17951 Nauticam Atomos Shogun housing mounting system P N 17952 Nauticam Atomos Shogun h...

Страница 32: ...16243 HDMI A D Cable in o 5m Length for RED DSMC2 C200 EVA1 Internal Cable HDMI 1 4 Input HDMI 2 0 Input P N 25077 M24D1R205 M28A1R170 HDMI 2 0 Cable for NA T3 to use with Ninja V housing P N 25079 M2...

Страница 33: ...length P N 25059 SDI cable extension adaptor P N 25084 M24D1R270 M28A1R170 HDMI 2 0 Cable for NA EM1X to use with Ninja V housing P N 25085 M28C1R200 M28A1R170 HDMI 2 0 Cable for NA Z7V to use with N...

Страница 34: ...4 P N 25062 25063 SDI cable in 5m 30m length for connection between SDI Bulkheads P N 25064 25065 SDI surface monitor cable in 15m 45m length for connection from SDI Bulkhead to Surface Monitor on lan...

Страница 35: ...35...

Отзывы: