Nautic YAPALONG 4000 Скачать руководство пользователя страница 3

BINDING PROCEDURE

Note:

1.

Binding needs to be done under minimum radio interference environment,

which means no cellphone, no computer, no Bluetooth, and no electrical

control panel nearby.

2.

After binding procedure, there is no need to do binding again next time for

the same group.

03

CLOSE BODY BLOCKING

1.

placing bodies in between

antennas causes communication

signs being blocked

ANTENNA TOUCHING BODY

2.

Human body is mainly water so it

absorbs RF wave. Water absorbs

RF (radio frequency) wave.

06

No close body blocking

No RF absorption

No close body blocking

Partial RF absorption

Partial close body blocking

due to low position

Partial RF absorption

HOW TO MAXIMIZE RANGE

To obtain maximum range is to eliminate blocking obstacles at line of sight. 

The range is greatly reduced when the obstacle is very close to the antenna. 

We need to avoid the following scenarios:

Total close body blocking

Partial RF absorption

Total close body blocking

Partial RF absorption

WEARING POSITION ANALYSES:

A. BINDING PROCEDURE FOR REGULAR UNITS

1.

Power down all units with good batteries installed.

2.

    

Power up 1st unit until RED LED is solid on. Hold down UP and DOWN

buttons simultaneously for 3 seconds until GREEN and AMBER LEDs begin to

flash alternatively. Release buttons for 5 or more seconds, both LEDs stop

blinking and all 3 LEDs remain solid on.

3.

Power up 2nd unit until RED LED is solid on. Hold down UP and DOWN

buttons simultaneously for 3 seconds until GREEN and AMBER LEDs begin to

flash alternatively. Release buttons for 5 or more seconds, both LEDs stop

blinking  and  only  RED  and  GREEN  remain  solid  on.  If AMBER  is  also  on,

restart Binding from Step1.

4.

Repeat Step3 for the rest units.

5.

Power down all units (incl. the 1st one) in random sequence. Then power up

all units in random sequence. So far Binding is done. If in doubt, repeat the

entire procedure.

B. ORDER FOR BINDING LISTENER UNITS

LISTENER units can be added to existing Yapalong group as listen-only units. 

Regardless of the previous grouping state, the entire group has to be bound 

again. The binding procedure is the same as the one for REGULAR units.

In addition we need to follow the order below to bind:

1.

Set 1st REGULAR into Binding mode.

2.

Set 2nd REGULAR into Binding mode.

3.

Set all LISTENERs into Binding mode one by one.

4.

Set the rest REGULARs into Binding mode one by one.

Отзывы: