![Nautel XR12 Скачать руководство пользователя страница 73](http://html2.mh-extra.com/html/nautel/xr12/xr12_operation-and-maintenance-manual_3622936073.webp)
XR12 Operations and Maintenance Manual
Test and adjustment
Page 5-4
Issue 3.1 2013-03-14
Non-standard adjustments
Complete the following non-standard adjustments only as directed by a troubleshooting or
replacement procedure in the
XR12 Troubleshooting Manual
:
•
•
•
RF drive symmetry
Measure the symmetry of the RF drive being applied from the active RF synthesizer PWB to the RF
power modules as follows:
1. Select exciter A as the active exciter.
2. Connect an oscilloscope to BNC connector J5 [
RF DRIVE (TEST)
] on the RF drive buffer
PWB.
3. The oscilloscope should indicate a symmetrical (50% duty cycle) square wave with a nominal
amplitude of 15 V peak-to-peak.
4. Adjust exciter A's RF synthesizer PWB's
SYMMETRY
potentiometer (R32) to obtain a 50%
duty cycle.
5. If an external RF drive source is used, adjust the RF drive source to obtain a symmetrical
square wave. If necessary, adjust the external generator according to its maintenance manual.
6. Select exciter B as the active exciter. Repeat
through
for exciter B.
7. Disconnect the oscilloscope from J5 of the RF drive buffer PWB.
Содержание XR12
Страница 2: ...left blank intentionally...
Страница 4: ...left blank intentionally...
Страница 10: ...XR12 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Страница 18: ...XR12 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Страница 55: ...XR12 Operations and Maintenance Manual Operating the transmitter Page 2 30 Issue 3 1 2013 03 14...
Страница 63: ...XR12 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Страница 69: ...XR12 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Страница 80: ......