Calibrating B+ Voltage - Using the Front Panel UI
The front panel UI’s
B+ Settings
menu (see
) allows for setting of the B+ Limit setpoint
(high voltage alarm level; nominally 420 V) or a B+ calibration. The calibration field allows you to enter
a measured B+ voltage to calibrate the B+ based on an externally measured B+ level.
Figure 3.2.136: Factory Settings - B+ Settings Menu
Use the up and down buttons to move the cursor to the desired item and then press the right button to
enable editing.
shows the two editing screens for the
B+ Settings
menu. Within either
of the editing screens, use the up and down buttons to edit the setting. Press the accept (checkmark)
button to save the change. Press cancel (
X
) to discard changes and return to the previous menu.
Figure 3.2.137: B+ Settings Editing Screens
Set the B+ limit setpoint for the transmitter between 0 and
450 V, in 1 V increments. Default setting is 420 V. Press the
cancel (
X
) button to discard changes and return to the
previous menu.
Set the B+ calibration value, from a known measured source,
between 0 and 450 V, in 0.1V increments. Press the cancel
(
X
) button to discard changes and return to the previous
menu.