NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Page 2-70
Issue 6.0 2019-01-31
Viewing alarm details
The
Transmitter Status
page displays a table that lists the active alarm details under the
following columns:
•
Device
- identifies the alarms by their originating device (e.g., Controller, Exciter A,
etc.)
•
Alarm
- identifies the type of alarm (alarm name).
•
Level
- identifies the severity level of the alarm
Status button colour indications
• When the
Status
button is red, one or more active alarms are indicating that the trans-
mitter may be in an ‘off-air’ state.
• When the
Status
button is yellow, one or more active alarms are indicating that the
transmitter is still ‘on-air’, but may be at reduced power.
• When the
Status
button is green, no alarms are being reported and the transmitter is
operating normally.
Resetting alarms
When an alarm is present, use the
Reset
button (
screen, to clear any latching alarms that are holding the transmitter in an “off-air” state. If the
offending alarm has cleared, then the transmitter should resume operation.
Figure 2.52: Logs - Reset
= low (RF output not affected)
= medium (RF output may be reduced)
= high (RF output may be inhibited)
Содержание NX15
Страница 2: ......
Страница 4: ......
Страница 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Страница 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Страница 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Страница 30: ......
Страница 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Страница 177: ......