NX15/NX25 Operations and Maintenance Manual
Description
Issue 6.0 2019-01-31
Page 1-9
RF Output Network
See electrical schematic
SD-5
and
. The combined RF output is filtered
through an RF network consisting of two “T” networks with a shunt third harmonic trap, and
then provided to the antenna system. The RF output is monitored by an RF current probe, RF
voltage probe, and directional coupler. Samples from these probes are provided for control and
“VSWR Protection” on page 1-10
). A static drain choke provides a dc
short to ground to dissipate static build-up on the antenna system, and an adjustable spark gap
provides protection for the transmitter output from lightning events on the antenna.
Figure 1.2: RF Output Network
RF
Pwr Mdl 1
RF 1 (+)
A43
Di
recti
onal
C
oupl
er
RF Voltage Sample
Forward Power
RF Current Sample
RF 1 (-)
L
Shu
n
t Ca
pacitor
Bank
A44
Sta
tic Drain
Paral
lel
Ca
pacitors
E1 Spark
gap
RF Out
to Antenna
L
L
Series Combining
Transform
e
r
Shu
n
t Ca
pacitor
Bank
Sample
Reflected Power
Sample
A42
RF Curre
nt Probe
RF Pwr Md
l 2
RF 2 (+)
RF 2 (-)
RF
Pwr Mdl 3
RF 3 (+)
RF 3 (-)
RF Pwr Md
l 10
RF 10 (+)
RF 10 (-)
A41
Voltage Probe
L
Содержание NX15
Страница 2: ......
Страница 4: ......
Страница 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Страница 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Страница 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Страница 30: ......
Страница 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Страница 177: ......