NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Issue 6.0 2019-01-31
Page 2-125
Remote outputs
Using the parameters from the
Outputs
tab (see
), you can configure up to 16
remote outputs that indicate either the presence of various alarms or the status of operator
controlled circuits.
Nautel sets remote output defaults prior to shipping. See the
NX15/NX25 Pre-installation
Manual
for details. If necessary, re-configure the remote outputs as follows:
Figure 2.95: Remote I/O - Output Parameters
1. On the left side of the page, select the desired remote output (1 through 16) from the
list. Note: you can configure remote outputs 1 through 16 for one of a variety of
monitoring outputs.
2. On the right side of the page, assign a name to the remote output by pressing
Channel
and selecting one of the following options:
•
Not Assigned
- No alarm or status parameter is monitored.
•
Remote Enabled
- Active logic level indicates the transmitter’s remote control is
enabled. Inactive logic level indicates the transmitter is in local control only.
•
RF On/Off
- Active logic level indicates the transmitter’s RF power stage is on
(enabled). Inactive logic level indicates the transmitter’s RF power stage is off.
•
Active Exciter
- Active logic level indicates that exciter A is active. Inactive logic level
indicates that exciter B is active.
•
Auto Changeover
- Active logic level indicates that the automatic exciter changeover
function is enabled.
Exit page
Outputs tab
Current
logic level
Содержание NX15
Страница 2: ......
Страница 4: ......
Страница 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Страница 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Страница 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Страница 30: ......
Страница 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Страница 177: ......