NX100 Pre-installation Manual
Planning control/monitor connections
Issue 3.2 2017-03-31
Page 8-9
Remote outputs
Up to 16 remote outputs, that indicate either the presence of various alarms or the status of operator
controlled circuits, are available for remote monitoring on connectors J3, J4 and J5 on the remote
interface PWB (A11A4). The sources and active logic levels of these remote outputs are user-defined.
See
for a list of output options and their descriptions. See
for the associated output terminals and status LEDs (see
remote interface PWB.
A switching device for each remote output provides the desired active logic when a true condition
exists. Nautel presets all remote outputs for Logic ‘0’ Active.
If the remote output is configured as Logic ‘0’ Active (see the
NX100 Operations and Maintenance
Manual
), then the remote output’s switching circuit will provide a current-sink-to-ground when a logic
true condition exists and an open collector for a logic false condition.
If the remote output is configured as Logic ‘1’ Active (see the
NX100 Operations and Maintenance
Manual
), then the remote output’s switching circuit will provide an open collector when a logic true
condition exists and a current-sink-to-ground for a logic false condition.
LED configuration
The remote interface PWB contains a bi-colour LED (DS1 through DS16) and a shorting jumper
(E1 through E16) for each of the 16 remote outputs. Each LED can be configured to glow green for
a status output or red for an alarm output, by setting the position of the associated shorting jumper.
For a status output, install the shorting jumper to short positions 1 and 2 of its post. For an alarm
output, install the shorting jumper to short positions 2 and 3 of its post. See
to determine the LED and shorting jumper associated with each remote output.
Below each LED is a blank, white label to allow for labelling of the status/alarm output.
Remote output connections
Remote outputs 1 through 16, as required, connect to terminals of connectors J3, J4 and J5 on the
remote interface PWB (A11A4). See
to determine the output terminal
associated with each remote output.
Содержание NX100
Страница 1: ...NX100 Transmitter Pre installation Manual Document NHB NX100 PRE Issue 3 2 2017 03 31 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...NX100 Pre installation Manual Page 1 viii Issue 3 2 2017 03 31...
Страница 10: ...NX100 Pre installation Manual Page x Issue 3 2 2017 03 31...
Страница 22: ...NX100 Pre installation Manual Page xxii Issue 3 2 2017 03 31...
Страница 24: ...NX100 Pre installation Manual Page xxiv Issue 3 2 2017 03 31...
Страница 28: ...NX100 Pre installation Manual Description Page 1 4 Issue 3 2 2017 03 31...
Страница 32: ...NX100 Pre installation Manual Pre installation tasks Page 2 4 Issue 3 2 2017 03 31...
Страница 42: ...NX100 Pre installation Manual Physical requirements Page 3 10 Issue 3 2 2017 03 31...
Страница 60: ...NX100 Pre installation Manual Electrical requirements Page 5 10 Issue 3 2 2017 03 31...
Страница 85: ...NX100 Pre installation Manual Planning control monitor connections Page 8 16 Issue 3 2 2017 03 31...
Страница 89: ...NX100 Pre installation Manual Parts and tools Page 9 4 Issue 3 2 2017 03 31...
Страница 95: ...NX100 Pre installation Manual Pre installation assistance Page 10 6 Issue 3 2 2017 03 31...
Страница 98: ......