Figure 1.2: Module Status Screen
RF power module fault validation
Each RF power module has a multi-colour LED on its front panel, which can help in identifying a
fault and allowing you to determine whether remedial action is required now or later.
Identify and isolate a defective RF power module, and verify the nature of the defect by checking the
LED on the RF power module’s front panel. Note which RF power module is not operating normally
and producing RF power (i.e., LED is not solid green). Record which RF power modules are
displaying an alarm and the state of its LED (see below).
For all
Module
alarms, the
Description and Troubleshooting Action
includes the expected LED colour for the AUI alarm being described.
– Green: Module is operational
– Green/Red: Module is operational, but has a non-inhibiting fault.
– Amber: Module is inhibited, but in a ready state (i.e., RF off).
– Red: Module is inhibited by a fault, or serially.
– Red/Amber: Module is not communicating with the AUI/Controller.
Содержание NV5
Страница 2: ......
Страница 4: ......
Страница 8: ...NV5 NV3 5 Troubleshooting Manual Page viii Issue 3 2 2014 12 10...
Страница 168: ...NV5 NV3 5 Troubleshooting Manual Wiring connector lists Page 4 16 Issue 3 2 2014 12 10...
Страница 174: ...NV5 NV3 5 Troubleshooting Manual Reading Electrical Schematics Page 5 6 Issue 3 2 2014 12 10...
Страница 196: ...Issue 3 2 2014 12 10 SD 20 Figure SD 20 Power Amplifier Pallet CD2011B...
Страница 212: ...Issue 3 2 2014 12 10 MD 6 Figure MD 6 NAI17 RF Drive Splitter Changeover Assembly A2 A1...
Страница 213: ...Issue 3 2 2014 12 10 MD 7 Figure MD 7 Ac Distribution Assembly 206 5150 01...
Страница 217: ...Issue 3 2 2014 12 10 MD 11 Figure MD 11 NAL09A 2 Input Reject Load Assembly A1...
Страница 227: ......