GV60 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 1.0 2018-01-01
PAGE 4.1.33
Troubleshooting Tips
Power Supply Module and LVPS Faults - see page 4.1.38
AUI Screen Lockup
If the local AUI screen locks up, perform the following steps to restore normal AUI operation:
1.
If you also use a PC for remote AUI control/monitoring of the transmitter, use the PC to navigate to
the
System Settings
page (from the
Menu
options). Select
Reset
and click the
Reboot AUI
button. If the local AUI is non-responsive (locked up) or this does not restore operation of the AUI,
proceed to
2.
Open the front door and use the controller’s UI to navigate to the
System Settings -> SBC Reset
screen. Select
Force SBC Reset
and press accept to save the changes (see the GV60 Operations &
Maintenance Manual). If this does not restore operation of the AUI, proceed to
3.
Remove the rear panel to gain access to the rear of the controller module (A4). From the rear
panel, use a suitable tool to activate the
SBC RESET
button (next to the
CONSOLE A2J8
D-sub
) via the rear panel clearance hole.
Figure 4.1.6: SBC Reset Button (partial rear view of controller A4)
Содержание GV60
Страница 2: ......
Страница 4: ......
Страница 8: ...GV60 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 1 0 2018 01 01 ...
Страница 102: ...GV60 TROUBLESHOOTING MANUAL PARTS LISTS PAGE 4 2 12 VERSION 1 0 2018 01 01 ...
Страница 463: ...VERSION 1 0 2018 01 01 MD 17 Figure MD 17 NAPA31C Power Amplifier PWB Q1 ...
Страница 466: ...VERSION 1 0 2018 01 01 MD 20 Figure MD 20 NAI23A RF Drive Splitter Changeover Assembly FRONT BACK ...
Страница 473: ...VERSION 1 0 2018 01 01 MD 27 Figure MD 27 NAL17 4 Input Reject Load Assembly TOP VIEW END VIEW 2 INPUT REJECT PWB A1 ...
Страница 475: ...GV60 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 1 0 2018 01 01 ...
Страница 476: ......