4.
Close the external interlock (if installed). If an external interlock is not installed, simulate the
closing of the external interlocks by applying a short circuit between TB1-1 and TB1-2 of the
remote interface PWB (A16). Alternatively, you can apply a short circuit between pins 19 and 20 of
the
REMOTE I/O-A (A1J2A)
connector on the rear of the controller (A4).
NOTE
: An interlock jumper (Nautel Part # 211-5060) is provided in the GV10/GV7.5’s ancillary kit. It is
intended to plug directly into the
INTLK
inputs (TB1-1 and 2), on the remote interface PWB (A16) or
into the
REMOTE I/O-A (A2J5A)
connector (pins 19 and 20), on the rear of the controller (A4). This
jumper cannot be used if you are using a D-sub connector to make other remote I/O connections to the
controller. Instead, you must solder a jumper between pins 19 and 20 of the mating connector (Nautel
Part # JS28, also provided in the ancillary kit).
5.
Set the switch on the front of each RF power module to its
ENABLE
position.
Commissioning
NOTE
: The following procedures require the use of the transmitter’s advanced user interface (AUI). If
you require assistance to navigate the AUI, refer to the GV10/GV7.5 Operations & Maintenance Manual
for more information.
Turning on the Transmitter
1.
Switch on the ac power at the service entrance to turn on the transmitter. Confirm the ac voltage,
noting the CSA label on the back of the transmitter.
2.
Check the alarm and status indications on the front door’s AUI (
Transmitter Status
page). See the
GV10/GV7.5 Operating and Maintenance Manual
.
3.
Select
Local
control.
4.
Using the AUI, select Preset 4, which is factory set for minimum RF output power (in FM mode).
5.
Press
RF On
. The
RF On
button will turn green.
6.
Increase the power to normal operating levels while monitoring the
Transmitter Status
page for
alarms.
7.
Set up or select the desired operating preset. See the
GV10/GV7.5 Operating and Maintenance
Manual
.
8.
Set the correct time and date on the AUI display. See the
GV10/GV7.5 Operating and Maintenance
Manual
.
Содержание GV10
Страница 2: ......
Страница 4: ......
Страница 8: ...GV10 GV7 5 INSTALLATION MANUAL PAGE 2 VIII VERSION 3 0 2014 11 01...
Страница 22: ...GV10 GV7 5 INSTALLATION MANUAL CONNECTING TO STATION REFERENCE GROUND PAGE 2 4 2 VERSION 3 0 2014 11 01...
Страница 32: ...GV10 GV7 5 INSTALLATION MANUAL INSTALLING PROGRAM INPUTS PAGE 2 7 4 VERSION 3 0 2014 11 01...
Страница 38: ...GV10 GV7 5 INSTALLATION MANUAL INSTALLING CONTROL MONITOR WIRING PAGE 2 8 6 VERSION 3 0 2014 11 01...
Страница 48: ...GV10 GV7 5 INSTALLATION MANUAL PARTS AND TOOLS PAGE 2 10 4 VERSION 3 0 2014 11 01...
Страница 58: ...GV10 GV7 5 INSTALLATION MANUAL PRE INSTALLATION INSTALLATION ASSISTANCE PAGE 2 11 10 VERSION 3 0 2014 11 01...
Страница 60: ...GV10 GV7 5 INSTALLATION MANUAL LIST OF TERMS PAGE 2 12 2 VERSION 3 0 2014 11 01...
Страница 61: ......