GV10/GV7.5 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 4.1.30
VERSION 3.2 2016-03-10
Rack #: +15V Fail
Power Supply (red)
This alarm occurs if the +15 V supply on the module control/interface PWB
(A3) is outside its acceptable voltage range (b13.5 and +16.5 V).
Rack #: +3.3V Fail
Power Supply (red)
This alarm occurs if the +3.3 V supply on the module control/interface PWB
(A3) is outside its acceptable voltage range (b3.0 and +3.6 V).
Rack #: +5V Fail
Power Supply (red)
This alarm occurs if the +5 V supply on the module control/interface PWB
(A3) is outside its acceptable voltage range (b4.5 and +5.5 V).
Device and
Alarm Name
(AUI, UI)
Controller Front
Panel LED (color)
Description and Troubleshooting Action
Содержание GV10
Страница 2: ......
Страница 4: ......
Страница 8: ...GV10 GV7 5 TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 3 2 2016 03 10...
Страница 84: ...GV10 GV7 5 TROUBLESHOOTING MANUAL RESPONDING TO ALARMS PAGE 4 1 76 VERSION 3 2 2016 03 10...
Страница 236: ......
Страница 292: ...VERSION 3 2 2016 03 10 SD 36 Figure SD 36 NAFP109B Output Power Probe and Sample PWBs...
Страница 296: ...VERSION 3 2 2016 03 10 SD 40...
Страница 300: ...GV10 GV7 5 TROUBLESHOOTING MANUAL MECHANICAL DRAWINGS PAGE 4 5 4 VERSION 3 2 2016 03 10...
Страница 313: ...VERSION 3 2 2016 03 10 MD 13 Figure MD 13 NAPA31C Power Amplifier PWB Q1...
Страница 316: ...VERSION 3 2 2016 03 10 MD 16 Figure MD 16 NAI23A 01 RF Drive Splitter Changeover Assembly FRONT BACK...
Страница 318: ...VERSION 3 2 2016 03 10 MD 18 Figure MD 18 NAL15 3 Input Reject Load Assembly L2 4 INPUT REJECT PWB TOP VIEW END VIEW...
Страница 324: ...GV10 GV7 5 TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 3 2 2016 03 10...
Страница 325: ......