Determine what the TUNING and LIMIT LEDs indicate for both the L and R tuning.  L and R TUNING MAX 
and MIN LIMIT LEDs should turn ON only at extremes of travel (see figure 4 & 5).  Otherwise limit sensor 
may be defective.  

Note:  L tune error may also cause R tune error so check L tune first. 

Fig. 2

Ensure the TUNE SETUP and INHIBIT LEDs     are 
OFF.  Ensure the +5V, +12V-A and +12V-B 
LEDs      are on and the CPU OK LED       is 
flashing.  

4

5

Select LOCAL control (LED ON) to 
activate INCREASE and DECREASE 
switches.  

6

Press INCREASE or DECREASE L TUNING switch, 
verify auto tune moves coils back to previous 
location.  

If coils do not return to previous position consult 
tuning procedure in ATU manual or repeat tuning 
pocedure from step 1

Note: If necessary switch OFF transmitter and change coil taps to increase or decrease the inductance as 
described in the Technical Instruction Manual.  