21
20
2.3 Deleting user
Step
Action
Key
1.
Press and hold the ‘3’ button until the red light stays on
3
2.
Key in the master code, for example 5678913
5678913
3.
Key in the ID code, for example 6
(the red light goes out)
06
The user code has been deleted. Only the master code remains valid. If the user code deletion is unsuccessful,
you hear a long signal. In that case, start again at step 1 for deleting the user code.
3. Opening delay and opening window
The opening delay can be 1 to 99 minutes:
This the waiting time before you can open the lock.
The opening window time can be 1 to 19 minutes:
You have to enter the code again to open the safe during this window (the period in which you can open it).
Key in code - start opening delay
Waiting time opening delay
Opening window - re-enter your code
3.1 Programming the opening delay and opening window
Make sure that the safe door is open while you change the opening delay and window (key in seven digit code).
If the red light goes out during programming, you have waited too long to make an entry. In that case, start again
at step 1.
Step
Action
Key
1.
Press and hold the ‘9’ button until the red light stays on
9
2.
Key in the master code, for example 5678913
5679813
3.
Enter the opening delay using two digits, for example
10 minutes
10
4.
Enter the opening window using two digits, for example
5 minutes
05
5.
Repeat the opening delay time
10
6.
Repeat the opening window time
(the red light goes out)
05
3.2 Opening with opening delay and opening window
Step
Action
Key
1.
Enter the user or master code, for example 5678913
5678913
2.
The opening delay time starts, the red light illuminates every
few seconds
3.
When the opening delay has elapsed, you will hear an audible
signal and the opening window begins. The light illuminates
every few seconds.
4.
Enter the user or master code, for example 5678913
5678913
5.
Open the handgrip within 3 seconds, and the safe is open
3.3 Changing the opening delay
You can only change the opening delay during the opening window.
Step
Action
Key
1.
Enter the user or master code, for example 5678913
5678913
2.
The opening delay time starts, the red light illuminates every
few seconds
3.
When the opening delay has elapsed, you will hear an audible
signal and the opening window begins. The light illuminates
every few seconds.
4.
Press and hold the ‘9’ button until the red light stays on
9
5.
Key in the master code, for example 5678913
5678913
6.
Enter the opening delay time using two digits,
for example 20 minutes
20
7.
Enter the opening window time using two digits,
for example 5 minutes
05
8.
Repeat the new opening delay time
20
9.
Repeat new opening window time.
The opening delay has now been changed.
05