Bio-logic

®

Select the appropriate ear tip size and place it on the probe tip.  
Insert the probe in the ear making sure that the ear tip fits tightly into the ear canal.

Select the test ear by pressing either the Right or Left button. Select Cartoon mode to start the test showing
a cartoon instead of the progress bar. This can be changed during the test by tapping on the plane
icon at the bottom of the device screen.

DPOAE diagnostic / high reolution

Connect the probe to the red connector.  
Select one of the Presets for DPOAE Diagnostic.

Содержание Otometrics Bio-logic AuDX PRO

Страница 1: ...pS 45 45 75 55 55 otoinfo natus com Natus Medical Incorporated 1 800 289 2150 otoorder us natus com www otometrics com Bio logic AuDX PRO quick start Quick start guide Doc No 7 26 1385 EN 00 Part No 7...

Страница 2: ...options can vary depending on your set up Turning On Off and changing the device Start menu On off button on right side Power supply connector Battery status Current time Customize settings Turn off d...

Страница 3: ...he probe to the red connector Select one of the Presets for DPOAE Screening Select the appropriate ear tip size and place it on the probe tip Insert the probe in the ear making sure that the ear tip f...

Страница 4: ...l be performed prior to measurement A green light indicates successful calibration below left After successful ear probe calibration the test will start automatically Probe fit override for patients w...

Страница 5: ...onse Red right ear or blue left ear bars show response amplitude Grey bars show noise amplitude Retest frequencies that did not pass Print results to a label or to a pdf file Test other ear Switch to...

Страница 6: ...the ear tip fits tightly into the ear canal Select the test ear by pressing either the Right or Left button Select Cartoon mode to start the test showing a cartoon instead of the progress bar This ca...

Страница 7: ...sful ear probe calibration the test will start automatically Please note that the presets for DPOAE diagnostics are HiRes which allows testing frequencies in 10 Hz increments or up to 30 points per oc...

Страница 8: ...o get other views Green check marks indicate valid response Red or blue bars indicate response grey bars indicate noise Print results to a label or to a pdf file Outcome for each test sorted by f2 and...

Страница 9: ...t to make changes at any time without notice Please note that not all products displayed on our webpage or advertising materials are available in all territories Please contact your local distributor...

Отзывы: