 mini System User Manual  

 P/N 051440D

 

 

 

ii 

 

Caution: Federal Law (U.S.) restricts this device to sale or use by or 

on the order of a physician (or properly licensed practitioner). 
Natus is a registered trademark of Natus Medical Incorporated 
neoBLUE mini is a trademark of Natus Medical Inc. 
Biliband is a trademark of Nascor Pty, Ltd 
BiliBlanket is a registered trademark of Ohmeda. 
Bili-Meter is a trademark of Olympic Medical. 
© 2006 Natus Medical Inc. All rights reserved. 
This manual may not be reprinted or copied in whole or in part 

without written consent from Natus Medical Inc. The content of this 

manual may change without notice. 
 

Natus Medical Inc. 

1501 Industrial Road 

San Carlos, CA 94070 USA 

Tel1 650 802 0400 

Fax +1 650 802 0401 

  

Technical S1 888 496 2887 

Technical Service Fax +1 650 802 8680  

E-mail: [email protected] 

Customer S1 888 622 2427 

Customer Service Fax +1 650 802 6620 

E-mail: [email protected] 

  

International Support - Please contact your local Distributor.  

Distributor locations can be found at www.natus.com 

 

EU Representative 

Fischer-Zoth Diagnosesysteme GmbH 

Walter-Kolbenhoff-Str. 34 

D-82110 Germering 

Germany

 

 

 

 

 

 

Содержание neoBLUEmini

Страница 1: ...____________________________________________________________ User Manual...

Страница 2: ...ay not be reprinted or copied in whole or in part without written consent from Natus Medical Inc The content of this manual may change without notice Natus Medical Inc 1501 Industrial Road San Carlos...

Страница 3: ...2 General Safety Information 2 3 Safety Symbols 3 Components and User Controls 3 1 Components 3 2 User Controls 4 Assembly and Operating Instructions 4 1 Setting Up the Device 4 2 Preparing Infant fo...

Страница 4: ...bassinets or radiant warmers The light output is optimized to provide a peak intensity of 30 35 W cm2 nm Blue LEDs emit light in the range of 400 550 nm peak wavelength 450 470 nm This range correspon...

Страница 5: ...present danger or possible injury to the patient and or user Important An instruction provided to help ensure correct clinical results and provide quality assurance to the phototherapy procedures Cau...

Страница 6: ...er is recommended In addition use of reflective foils may cause hazardous body temperatures Monitor the infant s skin temperature per your hospital policy during phototherapy to avoid fluctuations in...

Страница 7: ...ous oxide or other anesthetic agents Warning Disconnect Electrical Power Always switch off the power and disconnect the power cord when cleaning the light Important Use of Nonstandard Components The u...

Страница 8: ...neoBLUE mini System User Manual P N 051440D 5 Natus Manufacturer WEEE Directive Waste from Electrical and Electronic Equipment Directive Symbol Product should not be disposed of in normal waste...

Страница 9: ...al safety by protecting the baby and the unit from incidental debris or fluids Arm The adjustable arm allows positioning of the light in multiple locations and angles The arm is adjustable in five loc...

Страница 10: ...se check the intensity of the light using a spectrophotometer per your institution s procedures see Section 6 1 Checking the Light Intensity The light has been calibrated with the Ohmeda BiliBlanket M...

Страница 11: ...inches 45 7 cm 22 25 W cm2 nm 48 square inches 309 7 cm Approximately 6 x 8 15 2 cm x 20 3 cm 4 3 Administering Phototherapy 1 Switch on power using the power switch Warning Operator Safety Sensitive...

Страница 12: ...122 F Fan not working Verify that vents are not blocked If the lens surface has become hotter than 50 C 122 F verify that the fan is functioning correctly Baby becomes too warm Fan not working Verify...

Страница 13: ...The light has been calibrated with the Ohmeda BiliBlanket Meter II to deliver a peak intensity of 30 35 W cm2 nm at a 12 inch 30 5 cm distance from the baby Please refer to section 9 of this manual or...

Страница 14: ...eter The intensity of the light is set at the factory to 30 35 W cm2 nm at a 12 inch 30 5 cm distance from the light enclosure This measurement is taken at the central area of the effective surface ar...

Страница 15: ...12 in over 6 hrs 18 F 10 C warmer than ambient at 30 5 cm over 6 hrs Electrical Mains 85 264 VAC 47 to 63 Hz Maximum Rating 0 7A 100 240V 50 60 Hz Safety Leakage current 100 A Audible Noise 60 dB Dim...

Страница 16: ...tem can be placed closer to the infant yielding a higher intensity or higher dosage treatment To adjust the neoBLUE mini light to the desired intensity when changing the distance please refer to the s...