485
/
631
Bit field
Name
Description
If parity is enabled, when the transmitted data is written into the register, the highest bit
of the data (the 7th or 8th bit depends on USART_CTRL1.WL bit) will be replaced by
the parity bit.
USART Baud rate register (USART_BRCF)
Address offset : 0x08
Reset value : 0x0000 0000
Note: When USART_CTRL1.UEN=1, this register cannot be written;The baud counter stops counting if
USART_CTRL1.TXEN or USART_CTRL1.RXEN are disabled respectively.
Bit field
Name
Description
31:16
Reserved
Reserved, the reset value must be maintained
15:4
DIV_Integer[11:0]
Integer part of baud rate divider.
3:0
DIV_Decimal[3:0]
Fractional part of baud rate divider.
USART control register 1 register (USART_CTRL1)
Address offset : 0x0C
Reset value : 0x0000 0000
Bit field
Name
Description
31:14
Reserved
Reserved, the reset value must be maintained
13
UEN
USART enable
When this bit is cleared, the divider and output of USART stop working after the current
byte transmission is completed to reduce power consumption. Software can set or clear
this bit.
0:USART is disabled.