451
/
631
Bit field
Name
Description
0: No general call address was received;
1: when I2C_CTRL1.GCEN=1, general call address was received.
3
Reserved
Reserved, the reset value must be maintained.
2
TRF
Transmitter/receiver
After detecting the stop condition (I2C_STS1.STOPF=1), repeated start condition or bus
arbitration loss (I2C_STS1.ARLOST=1), or when I2C_CTRL1.EN=0, the hardware clears it.
0: Data receiving mode;
1: Data transmission mode;
At the end of the whole address transmission stage, this bit is set according to the R/W bit of the
address byte.
1
BUSY
Bus busy
Hardware clears this bit when a stop condition is detected.
0: No data communication on the bus;
1: Data communication on the bus.
When detecting that SDA or SCL is low level, the hardware sets this bit to' 1';
Note:This bit indicates the bus communication currently in progress, and this information is still
updated when the interface is disabled (I2C_CTRL1.EN=0).
0
MSMODE
Master/slave mode
Hardware clears this bit when a stop condition is detected on the bus, arbitration is lost
(I2C_STS1.ARLOST=1), or when I2C_CTRL1.EN=0.
0: In slave mode;
1: In master mode.
When the interface is in the master mode (I2C_STS1.STARTBF=1), the hardware sets this bit;
I2C Clock control register (I2C_CLKCTRL)
Address offset: 0x1c
Reset value: 0x0000
Note: 1. F
PCLK1
is required to be an integer multiple of 10 MHz, so that a fast clock of 400KHz can be generated
correctly.
2. The CLKCTRL register can only be set when I
2
C is turned off (I2C_CTRL1.EN=0)
Bit field
Name
Description
15
FSMODE
I2C master mode selection
0: I2C in standard mode(duty cycle defaults to 1/1);
1: I2C in fast mode(duty cycle can be configured).
14
DUTY
Duty cycle in fast mode