Speed adjustment jumper 

 

 

 

 
 
 
 
 
 

Speed Adjustment 

The fan has three speeds which are selectable by changing the position of the jumper. The fan is factory set to 
Setting 3 - High speed. To change the speed setting, pull the jumper off the header pins and place back onto the 
desired position, see Fig14.  
Setting 1 is 

LOW SPEED 

Setting 2 is 

MEDIUM SPEED 

Setting 3 is 

HIGH SPEED 

 

 

 
C. 

OVER-HEATING PROTECTION.

 

 

The fan motor is fitted with Thermal Overload Protection. This is a one-shot thermal fuse. In the event of a fault 
condition the fan will be automatically switched off. If this occurs isolate the fan, and call your service engineer. 
 
 

 
D. 

SERVICING AND MAINTENANCE. 

 

WARNING: 

THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED  

FROM THE POWER SUPPLY DURING MAINTENANCE.

 

 

 
1.  At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build 

up of dirt or other deposits.  

 

The In-Line Mixed Flow fan has sealed for life bearings, which do not require lubrication. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Dimensions(mm) 

100 

125 

150 

200 

AØ 

98 

122 

147 

198 

BØ 

178 

178 

200 

220 

124 

124 

138 

138 

298 

259 

307 

300 

96 

96 

118 

130 

168 

168 

192 

195 

FIXING CTRS

 

120 

120 

162 

100 

FIXING CTRS

 

153.5 

153.5 

178 

180 

 

15 
 
 
 
 
 
 

Setting 1 
LOW SPEED 

Setting 2 
MEDIUM SPEED 

Setting 3 
HIGH SPEED 

Содержание Monsoon UMD PRO Series

Страница 1: ... THE ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS UMD PRO Mixed Flow In Line Fan Range UMD100SX PRO UMD100TX PRO UMD125SX PRO UMD125TX PRO UMD150SX PRO UMD150TX PRO UMD200SX PRO UMD200TX PRO 220 240V 50Hz IP44 Installation and Wiring Instructions ...

Страница 2: ...y be used in conjunction with the appropriate Monsoon products E It is recommended that the connection to the fan connecter terminals is made with flexible cable F When the Fan is used to remove air from a room containing a fuel burning appliance precautions must be taken to avoid back flow of gases into the room from the open flue of gas or other appliance Ensure that the air replacement is adequ...

Страница 3: ...ired in the exhaust duct where excessive levels of moisture are present in the air Ducting passing through an unheated roof void should be insulated Refer to Fig 15 for overall fan dimensions and fixing hole positions When siting the appliance ensure that there is sufficient space to allow access for any servicing and maintenance To gain access to the mounting holes proceed as follows A Using a cr...

Страница 4: ...terminal box cover screws Fig 13 6 Ensure the impeller rotates and is free from obstructions Timer models cannot be used with a speed controller Timer Adjustment The fan must be wired to a remote switch e g light switch When switched ON the fan will operate at the selected speed and will continue to run for a preset time after the fan is switched OFF The timer is factory set at 15 minutes approx T...

Страница 5: ...l be automatically switched off If this occurs isolate the fan and call your service engineer D SERVICING AND MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE 1 At intervals appropriate to the installation the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits The In Line Mixed Flow fan h...

Страница 6: ...6 ...

Страница 7: ...7 ...

Страница 8: ... TA7 0RY EU Authorised Representative National Ventilation Bedrijvenweg 17 7442 CX Nijverdal Nederland authorisedrep nationalventilation nl Website www nationalventilation co uk email info nvagroup co uk Sales and technical hotline 01823 690290 494754 D 0921 ...

Отзывы: