background image

 
 
 

 

 23 

www.national.com  

11.0 Appendix B - Installing and running the Wavevision 4 software

 

11.1 Install the WaveVision Software. 

 

Insert the WaveVision CD-ROM into your computer’s CD-ROM drive. 

 

The WaveVision software requires a Java

 Runtime Environment or Java

 Development Kit, 

version 1.4 or higher, from Sun Microsystems, Inc. For detailed information on WaveVision’s use 
of Java technology,

 

please see below. If your computer does not have this software, the 

WaveVision installer will instruct you on how to install it. 

 

Locate and run the 

WaveVision 4 Setup.exe

 program on the CD-ROM.  Follow the on-screen 

instructions to finish the install

 

11.2 Java™ Technology 

 

The WaveVision software uses Sun Microsystems

®

 Java technology.  The underlying Java software must 

be installed on your computer in order for the WaveVision software to run.  The software can run on top of 
either the Java Runtime Environment (JRE) or the Java Development Kit (JDK), version 1.4 or higher.  A 
suitable copy of the JRE is included on your WaveVision CD-ROM. 
 
The WaveVision installer will first look for an existing copy of the JRE or JDK on your computer.  If neither 
is found, the installer will instruct you to first install a JRE.  To do this, run the 

J2RE*.exe

 installer 

program off the CD-ROM.  Follow the on-screen instructions to finish the install. 
 
After a suitable JRE or JDK is installed, run the WaveVision installer again.  The installer will detect the 
Java software and configure the WaveVision software to use it. 
 
Java technology can allow software to run on different platforms.  However, the WaveVision software 
contains Windows specific hardware interface code and therefore is only currently supported under 
Windows. 

 

11.3 Automatic Device Detection & Configuration 

 

The WaveVision system provides automatic hardware detection and configuration for the device under 
test. The FPGA is re-programmed on the fly by the host PC when the Development board is turned on. 
 
Normally, the configuration process is totally transparent to the user, and requires no intervention. 
However, this process can be overridden if required by specifying a new Xilinx configuration image by 
clicking the Xilinx Image Settings button within the Capture Setting window (Settings -> Capture Settings). 
 

 

 

11.4 Windows Driver 

 

The WaveVision software communicates with the WaveVision hardware through the Windows device 
driver software. If you are unable to connect to the Wavevision board after installing the software, do the 
following to uninstall and reinstall the driver. Go to the Windows Control Panel and select System. If you 
are using Windows 2000/XP select the Hardware tab. Then click on Device Manager and go down to the 
Universal Serial Bus controllers. With the WaveVision board connected, you will see it (or an unknown 
device) listed. Right click on it and uninstall the driver. Then unplug and plug in the board again to reinstall 
the 

driver

Содержание ADC081500DEV

Страница 1: ... 24 2006 Revision A Development Board Instruction Manual ADC081500DEV Single 8 Bit 1 5 GSPS 1 2W A D Converter with Xilinx Virtex 4 XC4VLX15 FPGA Copyright 2006 National Semiconductor Corporation ADC081500DEV Development Board ...

Страница 2: ...9 7 4 Schematic Drawing ADC081500DEV Power Supplies 1 10 7 5 Schematic Drawing ADC081500DEV Power Supplies 2 11 7 6 Schematic Drawing ADC081500DEV Expansion Header Interface 12 8 0 Bill of Materials Page 1 of 2 13 8 1 Bill of Material Page 2 of 2 14 9 0 Using the Wavevision4 software with the ADC081500DEV 15 9 1 Getting Started 15 9 2 Control Panel 17 9 3 Serial Control Mode 19 9 4 Capturing Wavef...

Страница 3: ... board and the system also allows an external clock to be used if alternative sample rates are required The ADC connects to a Xilinx Virtex4 FPGA which stores up to 4K of data from each channel before transferring it through the USB interface to the PC 2 0 Board Assembly The ADC081500 Development Board comes in a low profile plastic enclosure and requires no assisted cooling due to its low power c...

Страница 4: ...click the FFT Tab 4 0 Functional Description The ADC081500 Development Board schematic is shown in Section 7 0 4 1 Input circuitry The input signal s to be digitized should be applied to the front panel SMA connectors labeled I CH and Q CH These 50 Ohm inputs are intended to accept a low noise sine wave signals To accurately evaluate the dynamic performance of this converter the input test signals...

Страница 5: ...t please contact you nearest National Semiconductor representative 5 1 Clock Jitter When any circuitry is added after a signal source some jitter is almost always added to that signal Jitter in a clock signal depending upon how bad it is can degrade dynamic performance We can see the effects of jitter in the frequency domain FFT as leakage or spreading around the input frequency as seen in Figure ...

Страница 6: ...6 www national com 7 0 Schematic Drawing ADC081500DEV Onboard Clock VCO PLL ...

Страница 7: ...7 www national com 7 1 Schematic Drawing ADC081500DEV Analog Inputs I Q Digital Trigger Input ...

Страница 8: ...8 www national com 7 2 Schematic Drawing ADC081500DEV ADC connected to Virtex4 FPGA ...

Страница 9: ...9 www national com 7 3 Schematic Drawing ADC081500DEV USB Interface ...

Страница 10: ...10 www national com 7 4 Schematic Drawing ADC081500DEV Power Supplies 1 ...

Страница 11: ...11 www national com 7 5 Schematic Drawing ADC081500DEV Power Supplies 2 ...

Страница 12: ...12 www national com 7 6 Schematic Drawing ADC081500DEV Expansion Header Interface ...

Страница 13: ...13 www national com 8 0 Bill of Materials Page 1 of 2 ...

Страница 14: ...14 www national com 8 1 Bill of Material Page 2 of 2 ...

Страница 15: ...ing the Wavevision 4 Software Ensure the board is connected to the 12V power supply included in the package and that the switch on the rear panel is pushed to the ON position The Green LED on the rear panel should be illuminated Connect the USB cable between the PC which has Wavevision 4 software installed and the ADC081500DEV board The USB port can also be found on the rear panel shown below If t...

Страница 16: ... on the Settings pulldown menu and then click Capture Settings as shown below This will display the System Settings Window which should appear as below If the board has not been detected click the Test button under the Communication heading and the development board should be found If the communications fail check that the USB drivers are installed correctly then disconnect and re connect the USB ...

Страница 17: ... board due to the ADC being single channel I and Q Display is not a valid selection I Q Interleaved is not a valid selection Temp Sensor Displayed below the Channel Selection tab is the die temperature of both the FPGA and the ADC Hardware Serial Control Hardware Pin Control The ADC is controlled by the logic states on the dedicated control pins The logic on these pins is determined by the setting...

Страница 18: ...Sets the full scale range to 650mV pk pk 870mV Full Scale Sets the full scale range to 870mV pk pk The Following Pull down Tabs are available whether the Control mode is Hardware or Serial Standby Disable Standby Enable all on board power regulators Enable Standby Board is put into standby mode All power is shutdown except USB power PDQ Disable Q Shutdown Q Channel is not available Enable Q Shutdo...

Страница 19: ...l Register Program the control panel display will be changed to the following view In this mode the register settings can be changed simply by clicking on the bits Doing so will toggle the bit value and any linear values such as Full Scale Range or Offset will automatically be updated The Reset Registers button at the bottom of the Control Panel will reset and write all the values to the power on ...

Страница 20: ...n the board is in standby mode TRG TRIGGER EVENT illuminates when the Trigger Input makes low to high transition OVR ADC OVER RANGE Illuminates when the I or Q channel exceeds the full scale range of the ADC CLK CLOCK INPUT flashes with 50 duty cycle if the ADC is receiving a good clock input PWR POWER illuminates when the external 12V is connected and the system is not in Standby UPL UPLOAD illum...

Страница 21: ...ATA BUS A N2 LVDS or CMOS C4 DATA BUS A P3 LVDS or CMOS D4 DATA BUS A N3 LVDS or CMOS C5 DATA BUS A P4 LVDS or CMOS D5 DATA BUS A N4 LVDS or CMOS C6 DATA BUS A P5 LVDS or CMOS D6 DATA BUS A N5 LVDS or CMOS C7 DATA BUS A P6 LVDS or CMOS D7 DATA BUS A N6 LVDS or CMOS C8 DATA BUS A P7 LVDS or CMOS D8 DATA BUS A N7 LVDS or CMOS C9 INPUT STROBE P D9 INPUT STROBE N C10 DATA BUS B P0 LVDS or CMOS D10 DAT...

Страница 22: ...22 www national com 10 3 System Block Diagram ...

Страница 23: ...s installed run the WaveVision installer again The installer will detect the Java software and configure the WaveVision software to use it Java technology can allow software to run on different platforms However the WaveVision software contains Windows specific hardware interface code and therefore is only currently supported under Windows 11 3 Automatic Device Detection Configuration The WaveVisi...

Страница 24: ...move and edit annotations To edit an annotation double click it with the arrow tool To delete an annotation select it with the arrow tool and press the Delete key on your keyboard Line Annotation Tool To draw lines on the plot select this tool Drag to draw new lines To add arrowheads or fix the endpoints of the line double click it with the arrow tool Text Annotation Tool To draw labels on the plo...

Страница 25: ...ays Clicking the FFT Options button at the top of the plot will display a dialog showing the options for that particular plot The software also maintains default options for new FFT plots which are editable You can edit the default FFT options by choosing Default FFT Options from the Settings menu The options are Windowing You may choose from one of five different window functions The window funct...

Страница 26: ...t file The contents can be either a sample set or a histogram provided with or without time information The simplest example of this would be a file with a single column of samples You can open tab delimited text files by choosing Open from the File menu you can interleave data from multiple columns and or files You can choose ReOpen to reopen the same file later with the same settings for example...

Страница 27: ...r sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user 2 A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect i...