Chapter 3
VXIpc 700 Series Configuration and Installation
VXIpc 700 Series User Manual
3-8
©
National Instruments Corporation
Ethernet Power-On Defaults
The VXIpc-700 Ethernet circuitry loads its power-on settings from an
EEPROM. Do not change W6 from its default setting as shown in
Figure 3-7a. Figure 3-7b shows the alternate position only for
informational purposes.
Figure 3-7.
Ethernet Power-on Defaults
Installing the VXIpc 700 Series
This section contains general installation instructions for the VXIpc-700.
Consult your VXIbus mainframe user manual or technical reference
manual for specific instructions and warnings.
1.
Plug in your mainframe before installing the VXIpc-700. The power
cord grounds the mainframe and protects it from electrical damage
while you are installing the module.
Warning
To protect both yourself and the mainframe from electrical hazards,
the mainframe should remain off until you are finished installing the VXIpc-700
module.
2.
Remove or open any doors or covers blocking access to the mainframe
slots.
3.
If you are installing the VXIpc-700 into a D-size mainframe, install a
support designed for installing C-size boards in D-size mainframes.
The VXIpc-700 has no P3 connector and cannot provide P3 Slot 0
control to VXI devices requiring this capability.
Caution
If the VXIpc-700 is not configured for automatic Slot 0 detection, be certain
that the slot you select in your VXIbus mainframe matches the VXIpc-700
configuration as either a Slot 0 device or a Non-Slot 0 device. If you install your
VXIpc-700 into a slot that does not correspond with the jumper setting, you risk
damage to the VXIpc-700, the VXIbus backplane, or both.
a. Ethernet Power-On Defaults
Loaded from EEPROM
b. Hardwired Ethernet Values
W6
W6
!