National Instruments VXI-8340 Series Скачать руководство пользователя страница 4

©

National Instruments Corporation

3

VXI-8340 Series

5. Select the destination for the installed files. The default is

C:\Program 

Files\National Instruments

.

6. Select the type of installation from the

Installation Options

screen:

Typical

setup prompts you to make high-level choices of which driver(s)

to install and the destination directories.

Custom

setup gives you more control over which driver components you

want installed on your system. This option is recommended for advanced
users.

7. Follow the prompts. Confirm that you are ready to install and click

Next

to

begin the installation.

8. Setup now copies the necessary files to your hard drive and creates program

icons.

Complete the Software Installation

1. Review the information in any

readme

files that Setup prompts you to read.

2. When the installation process completes, restart the system for the changes

to take effect.

Note

On some Windows systems, the OS will detect the MXI-3

interface as a “PCI Standard PCI-to-PCI Bridge,” and Windows may ask
you to specify the location of a driver information file (

.inf

) for the

device. If this occurs, accept the default choices by clicking

Next

when

prompted.

Содержание VXI-8340 Series

Страница 1: ...al Instruments VXI 8345 Manual Get Pricing Availability at ApexWaves com Call Today 1 800 915 6216 Email sales apexwaves com https www apexwaves com modular systems national instruments mxi 3 series VXI 8345 ...

Страница 2: ...ontroller Installing the Software Use the Setup program that came with your NI VISA NI VXI software to install the entire software package or a software update or to reinstall software in the event that your files are accidentally erased Some of the utilities rely on the LabWindows CVI Run Time Engine This software is installed if necessary during the NI VISA NI VXI installation To be compliant wi...

Страница 3: ...selections You can quit the Setup program at any time by pressing the Cancel button Setup is an interactive self guiding program that installs the NI VISA and NI VXI software and configures your system to use the software with the VXI 8340 series Follow these steps to perform the installation 1 Insert the CD ROM labeled NI VXI v 3 2 for Windows 2 Wait for Windows to launch the CD ROM installation ...

Страница 4: ...vanced users 7 Follow the prompts Confirm that you are ready to install and click Next to begin the installation 8 Setup now copies the necessary files to your hard drive and creates program icons Complete the Software Installation 1 Review the information in any readme files that Setup prompts you to read 2 When the installation process completes restart the system for the changes to take effect ...

Страница 5: ...and MXI 3 cable Caution To guard against electrostatic discharge touch the antistatic plastic packages to a metal part of your computer or chassis before removing the boards from their packages Your computer or chassis should be plugged in but powered off Figure 1 shows a system with a PCI bus equipped computer and a VXI chassis with a VXI 8340 series module Figure 1 Typical VXI System with a VXI ...

Страница 6: ...s and covers 3 Select an available PCI slot in your computer The slot you select should support bus mastering Refer to your computer documentation to determine if the slot you select supports bus mastering 4 Remove the corresponding expansion slot cover from the chassis 5 Align the bus connector on the PCI 8330 series with the PCI bus slot Figure 2 Installing the PCI 8330 Series Interface Board 1 ...

Страница 7: ...me chassis are not configured as system controller The VXI 8340 series default configuration automatically detects whether it should be the VXI system controller Caution Having more than one device configured as system controller can damage the VXI system 4 For VXI systems that include VME devices ensure that the VME devices are not configured in the upper 16 KB starting from 0xC000 of the A16 add...

Страница 8: ...ts of the VXI 8340 Series User Manual for more information regarding power up requirements for the VXI 8340 series controllers The manual is in PDF format on the NI VXI v 3 2 for Windows CD ROM 3 Turn on the host computer 4 If your system CMOS setup requires you to adjust PCI bus parameters do so at this time Note The PCI bus usually assigns IRQs and port addresses automatically However in some PC...

Страница 9: ...requirements for the VXI 8340 series controllers 2 After you run Resman you are ready to use MAX to configure the National Instruments hardware in your system interactively You can also configure MAX to run Resman automatically at every computer startup by selecting Tools NI VXI VXI Options 3 After you finish configuring the system through MAX verify the system configuration through one of the int...

Отзывы: