National Instruments Corporation
9
UMI Accessory User Guide — UMI-7764
Analog Input Terminal Block
For analog input wiring, the UMI-7764 has a 6-position terminal block,
which provides access to the four analog input channels on your motion
controller. Refer to Figure 1 to help you locate the analog input terminal
block on your UMI-7764 accessory. See Figure 8 for analog input terminal
block pinout information.
Figure 8.
UMI-7764 Analog Input Terminal Block Pin Assignments
Breakpoint Output/Trigger Input Terminal Block
For breakpoint output and trigger input wiring, the UMI-7764 has a
10-position terminal block. This terminal block provides access to the four
breakpoint outputs and the four trigger inputs. Refer to Figure 1 to help you
locate the breakpoint output/trigger input terminal block on your
UMI-7764 accessory. See Figure 9 for more information on breakpoint
output and trigger input wiring.
Figure 9.
UMI-7764 Breakpoint/Trigger Terminal Block Pin Assignments
Analog Input 4
Analog Input 3
Analog Input 2
Analog Input 1
Analog Reference (Output)
Analog Input Ground
Breakpoint 4
Breakpoint 3
Breakpoint 2
Breakpoint 1
Digital Ground
+5 V (Output)
Trigger 4
Trigger 3
Trigger 2
Trigger 1
Содержание UMI-4A