manualshive.com logo in svg
background image

©

 National Instruments Corporation

7

NI TB-2706 Installation Guide

CE Compliance

This product meets the essential requirements of applicable European Directives, as amended for 
CE marking, as follows:

73/23/EEC; Low-Voltage Directive (safety)

89/336/EEC; Electromagnetic Compatibility Directive (EMC)

Note

Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory 

compliance information. To obtain the DoC for this product, visit 

ni.com/certification

search by model number or product line, and click the appropriate link in the Certification column.

Waste Electrical and Electronic Equipment (WEEE)

EU Customers

At the end of their life cycle, all products 

must

 be sent to a WEEE recycling center. 

For more information about WEEE recycling centers and National Instruments WEEE initiatives, 
visit 

ni.com/environment/weee.htm

.

Where to Go for Support

The National Instruments Web site is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development self-help 

resources to email and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, 
Texas, 78759-3504. National Instruments also has offices located around the world to help address your 
support needs. For telephone support in the United States, create your service request at 

ni.com/

support

 and follow the calling instructions or dial 512 795 8248. For telephone support outside the 

United States, contact your local branch office:

Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020, 
Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 385 (0) 9 725 72511, 
France 33 (0) 1 48 14 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, 
Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28, 
Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, 
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 3390150, 
Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886, 
Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, 
Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545

Содержание Terminal Block NI TB-2706

Страница 1: ...l Instruments device The 70 screw terminals allow access to every pin on the connector plus two shield screw terminals for use with a shielded cable For M Series devices with two connectors this terminal block allows access to every pin on Connector 0 plus two shield screw terminals for use with a shielded cable but makes Connector 1 inaccessible Caution The TB 2706 is not designed for input volta...

Страница 2: ...nt Misuse of this equipment could result in a shock hazard Do not substitute parts or modify equipment Because of the danger of introducing additional hazards do not install unauthorized parts or modify the device Return the device to National Instruments for service and repair to ensure that its safety features are not compromised You must insulate all of your signal connections to the highest vo...

Страница 3: ...ver Note Your kit contains a pinout label for M Series devices only shown in Figure 2 This label adhered to the inside of the cover is a pin number to signal name reference For PXI 6143 pin connections refer to Figure 3 or the S Series User Manual 1 Top Cover Screw 2 Cover 3 Chassis Ground Lug 4 Strain Relief Screw 5 Terminal Block Mounting Screw 6 Strain Relief Bar 7 Signal Wire 8 Strain Relief O...

Страница 4: ...river 3 Use wire cutters and wire insulation strippers to strip no more than 7 mm of insulation from the wire ends 4 Loosen the screws in the screw terminals with the 0 10 in slotted screwdriver 5 Insert the stripped wires into the screw terminals Tighten the screws with the 0 10 in slotted screwdriver No bare wire should extend past the screw terminal Exposed wire increases the risk of short circ...

Страница 5: ...t the chassis is powered off before inserting the PXI PXIe module 1 Install the PXI PXIe module into the chassis and tighten the two module screws You must install the TB 2706 terminal block on the PXI PXIe module after the module is installed in the chassis 2 Guide the terminal block onto the connector 3 Tighten the two terminal block mounting screws Caution The TB 2706 is not designed for input ...

Страница 6: ...ive humidity 10 to 90 noncondensing Pollution Degree indoor use only 2 Altitude 2 000 m Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA 61010 1 Note For UL and other safety certifications refer to the product label or visit ni com certification sea...

Страница 7: ...m NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone supp...

Страница 8: ...al Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents 2005 2007 National Instruments Corporation All rights reserved 371459B 01 Apr07 ...

Отзывы: