Specifications

This section lists additional specifications for the NI TB-2643 used with the 
NI PXI-2532. All specifications are subject to change without notice. Visit 

ni.com/manuals

 for the most current specifications.

Input Characteristics

All input characteristics are DC, AC

pk

, or a combination unless otherwise 

specified.

Maximum switching voltage

Channel-to-channel..........................100 V

Channel-to-ground...........................100 V, CAT I

Caution 

This module is rated for Measurement Category I and intended to carry signal 

voltages no greater than 100 V. This module can withstand up to 500 V impulse voltage. 
Do 

not

 use this module for connections to signals or for measurements within 

Categories II, III, or IV. Do 

not

 connect to MAINs supply circuits (for example, wall 

outlets) of 115 or 230 VAC. Refer to the 

Read Me First: Safety and Electromagnetic 

Compatibility

 document for more information on measurement categories.

 

 

When hazardous voltages (>42.4 V

pk

/60 VDC) are present on any relay terminal, safety 

low-voltage (<42.4 V

pk

/60 VDC) cannot be connected to any other relay terminal.

Maximum current (per channel) .............0.5 A

DC path resistance ..................................<1.5 

Ω

Row and column protection
resistors (when used)  .............................100 

Ω

Bandwidth (–3 dB, 50 

Ω

 termination)

Typical

.............................................≥

11 MHz

Crosstalk (50 

Ω

 termination)

Channel-to-channel

10 kHz ......................................< – 75 dB

100 kHz ....................................< – 60 dB

1 MHz.......................................< – 40 dB

Содержание TB-2643

Страница 1: ... determine when to install the terminal block Make sure you have the following NI TB 2643 terminal block 1 8 in flathead and 1 Phillips screwdrivers Eight 2 mm jumpers Four 34 conductor 28 AWG 050 in pitch ribbon cable assemblies not included One 16 conductor 28 AWG 050 in pitch ribbon cable assembly not included Note Refer to the Accessories section for information about ordering the appropriate ...

Страница 2: ...6 Connect each ribbon cable to the appropriate headers on the column connection boards and the module interface board 7 Reassemble the terminal block Note For information about protection resistance and matrix expansion refer to the NI Switches Help Figure 1 NI TB 2643 Terminal Block 1 Top Cover Screw 2 Top Cover 3 Strain relief Screws 4 Strain relief Bar 5 Column Connection Board Screws 6 Lower C...

Страница 3: ...connection cable for column expansion National Instruments 779325 01 16 Conductor 05 in pitch ribbon cable assemblies Samtec FFSD 08 01 N 34 Conductor 05 in pitch ribbon cable assemblies Samtec FFSD 17 01 N J4 3 2 1 0 Pin 1 3 2 1 0 LOWER COLUMN CONNECTION BOARD C16 C16 C0 C0 C15 C15 UPPER COLUMN CONNECTION BOARD C31 C31 C47 C47 C63 C48 C48 C32 C32 C63 J2 J3 J2 J3 3 3 2 2 1 1 0 0 Pin 1 J3 3 2 1 0 P...

Страница 4: ...stics All input characteristics are DC ACpk or a combination unless otherwise specified Maximum switching voltage Channel to channel 100 V Channel to ground 100 V CAT I Caution This module is rated for Measurement Category I and intended to carry signal voltages no greater than 100 V This module can withstand up to 500 V impulse voltage Do not use this module for connections to signals or for meas...

Отзывы: