background image

4 of 10

 

www.smart-e-tech.com

 

SET-2090 Technical Description

 

 

Issue 03   

30/07/2019 

 

 

15

 

30

 

44 

14

 

29

 

43 

13

 

28

 

42 

12

 

27

 

41 

11

 

26

 

40 

10

 

25

 

39 

9

 

24

 

38 

8

 

23

 

37 

7

 

22

 

36 

6

 

21

 

35 

5

 

20

 

34 

4

 

SET-2090 Pinout 

 

J1 

J2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1.

 

JR2 Connector Pin Assignments

 

 

Signal

 

Description

 

 

 

Px.y 

Line y Port x 

GND

 

Ground connection

 

NC

 

No connection

 

 

 

 

15

 

 

30

 

 

44

 

 

14

 

 

29

 

  

43

 

 

13

 

 

28

 

 

42

 

 

12

 

 

27

 

 

41

 

 

11

 

 

26

 

 

40

 

 

10

 

 

25

 

 

39

 

 

9

 

 

24

 

 

38

 

 

8

 

 

23

 

 

37

 

 

7

 

 

22

 

 

36

 

 

6

 

 

21

 

 

35

 

 

5

 

 

20

 

 

34

 

 

4

 

 

19

 

 

33

 

 

3

 

 

18

 

 

32

 

 

2

 

 

17

 

 

31

 

 

 

16

 

 

 

 

15

 

 

30

 

 

44

 

 

14

 

 

29

 

  

43

 

 

13

 

 

28

 

 

42

 

 

12

 

 

27

 

 

41

 

 

11

 

 

26

 

 

40

 

 

10

 

 

25

 

 

39

 

 

9

 

 

24

 

 

38

 

 

8

 

 

23

 

 

37

 

 

7

 

 

22

 

 

36

 

 

6

 

 

21

 

 

35

 

 

5

 

 

20

 

 

34

 

 

4

 

 

19

 

 

33

 

 

3

 

 

18

 

 

32

 

 

2

 

 

17

 

 

31

 

 

 

16

 

 

 

P3.2+

 

P3.2- 

P3.1+

 

P3.1- 

P3.0+

 

P3.0- 

NC

 

NC 

P2.2+ 

P2.2- 

P2.1+

 

P2.1- 

P2.0+

 

P2.0- 

J1_Spare 

GND 

P1.2+ 

P1.2- 

P1.1+

 

P1.1- 

P1.0+

 

P1.0- 

NC

 

NC 

P0.2+

 

P0.2- 

P0.1+

 

P0.1- 

P0.0+ 

P0.0- 

 

P3.3+

 

 

P3.3-

 

 

REF_3 

 

REF_2

 

 

P2.3+ 

 

P2.3-

 

 

GND 

 

GND 

 

P1.3+

 

 

P1.3-

 

 

REF_1

 

 

REF_0

 

 

P0.3+

 

 

P0.3- 

 

P7.2+

 

P7.2- 

P7.1+

 

P7.1- 

P7.0+

 

P7.0- 

NC

 

NC 

P6.2+ 

P6.2- 

P6.1+

 

P6.1- 

P6.0+

 

P6.0- 

J2_Spare 

GND 

P5.2+ 

P5.2- 

P5.1+

 

P5.1- 

P5.0+

 

P5.0- 

NC

 

NC 

P4.2+

 

P4.2- 

P4.1+

 

P4.1- 

P4.0+ 

P4.0- 

 

P7.3+

 

 

P7.3-

 

 

REF_7 

 

REF_6

 

 

P6.3+ 

 

P6.3-

 

 

GND 

 

GND 

 

P5.3+ 

 

P5.3-

 

 

REF_5

 

 

REF_4

 

 

P4.3+

 

 

P4.3- 

 

Содержание SET-2090

Страница 1: ...and hardware installation procedures applicable to your application Note The guidelines in this document are specific to the SET 2090 The other components in the system might not meet the same safety ratings Refer to the documentation of each com ponent in the system to determine the safety and EMC ratings for the entire system MORE INFORMATION ON OUR WEBSITE www smart e tech com slsc 0X 2090 Pass ...

Страница 2: ...ic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television reception and prevent unacceptable performance degradation install and use this product...

Страница 3: ...without a labeling are optional The Ref Signal form the block diagram below is each connected to the corresponding Reference Signals on the Front connector Per connector 4 Reference Signals are available mapping each to four differential signals For example the Ref from Channel P0 0 is connected to the Ref_0 Signal which is on J1 and shared for channel P0 0 to P0 3 Ref_0 is for channel P0 0 P0 3 R...

Страница 4: ... 35 5 20 34 4 19 33 3 18 32 2 17 31 1 16 15 30 44 14 29 43 13 28 42 12 27 41 11 26 40 10 25 39 9 24 38 8 23 37 7 22 36 6 21 35 5 20 34 4 19 33 3 18 32 2 17 31 1 16 P3 2 P3 2 P3 1 P3 1 P3 0 P3 0 NC NC P2 2 P2 2 P2 1 P2 1 P2 0 P2 0 J1_Spare GND P1 2 P1 2 P1 1 P1 1 P1 0 P1 0 NC NC P0 2 P0 2 P0 1 P0 1 P0 0 P0 0 P3 3 P3 3 REF_3 REF_2 P2 3 P2 3 GND GND P1 3 P1 3 REF_1 REF_0 P0 3 P0 3 P7 2 P7 2 P7 1 P7 1...

Страница 5: ... P1 0 I O_4 P5 0 I O_20 P1 1 I O_5 P5 1 I O_21 P1 1 I O_5 P5 1 I O_21 P1 2 I O_6 P5 2 I O_22 P1 2 I O_6 P5 2 I O_22 P1 3 I O_7 P5 3 I O_23 P1 3 I O_7 P5 3 I O_23 P2 0 I O_8 P5 0 I O_24 P2 0 I O_8 P6 0 I O_24 P2 1 I O_9 P6 1 I O_25 P2 1 I O_9 P6 1 I O_25 P2 2 I O_10 P6 2 I O_26 P2 2 I O_10 P6 2 I O_26 P2 3 I O_11 P6 3 I O_27 P2 3 I O_11 P6 3 I O_27 P3 0 I O_12 P7 0 I O_28 P3 0 I O_12 P7 0 I O_28 P3...

Страница 6: ...n Assignments Row e d c b a 1 I O_1 I O_1 NC I O_0 I O_0 2 I O_3 I O_3 NC I O_2 I O_2 3 GND GND GND GND GND 4 I O_5 I O_5 NC I O_4 I O_4 5 I O_7 I O_7 NC I O_6 I O_6 6 GND GND GND GND GND 7 I O_9 I O_9 NC I O_8 I O_8 8 I O_11 I O_11 NC I O_10 I O_10 9 GND GND GND GND GND 10 I O_13 I O_13 NC I O_12 I O_12 25 15 11 1 e d c b a ...

Страница 7: ..._19 I O_19 NC I O_18 I O_18 17 GND GND GND GND GND 18 I O_21 I O_21 NC I O_20 I O_20 19 I O_23 I O_23 NC I O_22 I O_22 20 GND GND GND GND GND 21 I O_25 I O_25 NC I O_24 I O_24 22 I O_27 I O_27 NC I O_26 I O_26 23 GND GND GND GND GND 24 I O_29 I O_29 NC I O_28 I O_28 25 I O_31 I O_31 NC I O_30 I O_30 Table 4 XJ2 Connector Signal Descriptions Signal Description I O Input Output GND Ground connection...

Страница 8: ... com SET 2090 Technical Description Issue 03 30 07 2019 XJ3 Table 2 XJ2 Connector Pin Assignments Pins Signal H Instrument_0 G Instrument_0 F Instrument_1 E Instrument_1 D Fault_D C Fault_C B Fault_B A Fault_A H G F E D C B A ...

Страница 9: ...te Solid amber Module card is booting Blinking amber Chassis is communicating with the module card Error Handling LED Name LED Behavior Actions Power Off Checking the power supply of the chassis Checking the external power supply if used RDY Off Checking the power supply of the chassis Checking the external power supply if used Solid amber Waiting till boot process is finished Blinking amber Waiti...

Страница 10: ...ls Characteristics Property Condition Value Comment Module dimensions Excluding ejector 144 32mm x 30 48mm x 302mm H x W x D Standard SLSC card size Front Panel Connector 2x female DB 44 high density D Sub with 4 40 UNC screw lock For mating connectors and cables see below RTI Connector 2mm hard metric per IEC 61076 101 Any RTI marked Environmental Property Condition Value Comment Operating humidi...

Отзывы: