SCXI-1342 Cable Assembly Installation Guide

2

© National Instruments Corporation

Installation Procedure

Figure 1 illustrates the components of your SCXI system.

SCXI

1140 

SCXI Module

NB1 Ribbon Cable

Extra Male

Breakout Connector

(Optional Connection)

PC-LPM-16 Board

SCXI-1342

Adapter Board

Figure 1.  Connecting the SCXI-1342 to Your Data Acquisition Board and SCXI Module

Perform the following steps to install the SCXI-1342 cable:

1. Turn off the power to your computer and the SCXI chassis.

2. Install your SCXI module in the SCXI chassis, following the instructions in your module

user manual.

3. Set jumper W1 on the SCXI-1342 adapter board to the correct position for your system, as

shown in Figure 2.  When set to position A, the factory-default position, jumper W1 connects

pin 46 of the PC-LPM-16 to pin 46 of the module connector.  Position B breaks this

connection.  Leave jumper W1 in position A unless you are using an SCXI-1140 module and

are not supplying the HOLDTRIG signal to the module from the PC-LPM-16.  See your

SCXI-1140 User Manual

 for an explanation of the HOLDTRIG signal.

A

B

Position A

HOLDTRIG Connected

B

A

Position B

HOLDTRIG Disconnected

Figure 2.  Jumper W1 Settings

4. Plug the female right-angle module connector of the SCXI-1342 adapter board into the rear

signal connector of the SCXI module.