Chapter 1
Installing and Configuring the SCXI-1129
©
National Instruments Corporation
1-17
5.
Connect the HV8-BAN4 cable from the DMM to the HVAB connector
behind SCXI slot 4.
6.
Connect the SH9MD-9MD cable from the DMM to the AUX IN
connector.
7.
You can install any additional SCXI-1129 modules in any slot that has
an HVAB-backplane adapter behind it.
DMM in PXI Slot 8 Configuration
To install your DMM in PXI slot 8, follow these steps:
1.
Install your DMM in PXI slot 8.
2.
In the SCXI subsystem, install the 2-slot HVAB-backplane adapter
behind SCXI slots 3 and 4.
3.
Install additional 1-slot HVAB-backplane adapters behind SCXI
slots 1 and 2 if needed.
4.
Install the 8-position HVAB plugs to connect the HVAB-backplane
adapters as needed.
5.
Connect the HV8-BAN4 cable from the DMM to the HVAB connector
behind SCXI slot 4 of the SCXI subsystem.
6.
You can install any additional SCXI-1129 modules in any slot that has
an HVAB-backplane adapter behind it.
Note
The SH9MD-9MD is not required for this configuration.
Connecting the SCXI-1129 to the DMM in the PXI-1011 Chassis
You need the following items to complete the installation:
•
PXI-1011 chassis with the SCXI-1129 modules installed
•
HV8-BAN4 cable
•
DMM
•
1/8 in. flathead screwdriver
Consult your PXI-1011 and DMM documentation for additional
instructions and warnings. You should have already installed your
SCXI-1129 modules and any other SCXI modules in the chassis according
to their installation instructions. Before you proceed with your connections,
make sure you power off your SCXI chassis.