Chapter 2
Using the SCXI-1126
2-4
ni.com
The input signal range of an SCXI-1126 input channel is
−
0.5 to 4.5 V
referenced to its negative input. In addition, the input channels are
overvoltage protected to 250 V
rms
with power on or off at a maximum
of 5 mA
rms
sink or source.
SCXI-1126 Front Connector
This section provides detailed information about the front and rear signal
connectors. If you are creating a custom terminal block using the
SCXI-1330 terminal block, read this section for information on signal
locations on the front signal connector.
Table 2-1 shows the SCXI-1126 positive input channel locations in
Column A with their corresponding negative input channels located in
column C. The pin descriptions are given in Table 2-2, and the analog input
connections are discussed in the
section.