background image

SCC-DI01 Isolated Digital Input Module User Guide

6

ni.com

Electromagnetic Compatibility

Emissions................................................EN 55011 Class A at 10 m

FCC Part 15A above 1 GHz

Immunity ................................................EN 61326:1997 + A2:2001, 

Table 1

CE, C-Tick, and FCC Part 15 (Class A) Compliant

Note

For full EMC compliance, operate this device with shielded cabling. In addition, 

all covers and filler panels must be installed. 

CE Compliance

This product meets the essential requirements of applicable European 
Directives, as amended for CE marking, as follows:

Low-Voltage Directive (safety)..............73/23/EEC

Electromagnetic Compatibility 
Directive (EMC) .....................................89/336/EEC

Note

Refer to the Declaration of Conformity (DoC) for this product for any additional 

regulatory compliance information. To obtain the DoC for this product, visit 

ni.com/hardref.nsf

, search by model number or product line, and click the 

appropriate link in the Certification column.

Содержание SCC-DI01

Страница 1: ...sh When this symbol is marked on the product see the Read Me First Safety and Radio Frequency Interference document shipped with the product for precautions to take This icon denotes a note which aler...

Страница 2: ...at You Need to Get Started To set up and use the SCC DI01 you need the following items SC 2345 2350 with one of the following SCC PWR01 SCC PWR02 and the PS01 power supply SCC PWR03 requires a 7 to 42...

Страница 3: ...or connecting disconnecting any signal wires Plug the SCC DI01 into any digital input output socket J X 9 where X is 0 to 7 on the SC 2345 When you follow the procedure in the SCC Quick Start Guide t...

Страница 4: ...computer ground Propagation delay Low to high 10 s1 High to low 250 s1 Rise time 10 ns max Fall time 10 ns max Power Requirement Digital power 61 mW max Physical Characteristics Dimensions 8 89 cm 2 9...

Страница 5: ...ry 2 Environmental Operating temperature 0 to 50 C Storage temperature 20 to 70 C Humidity 10 to 90 RH noncondensing Maximum altitude 2 000 m Pollution Degree indoor use only 2 Safety The SCC DI01 mee...

Страница 6: ...iller panels must be installed CE Compliance This product meets the essential requirements of applicable European Directives as amended for CE marking as follows Low Voltage Directive safety 73 23 EEC...

Страница 7: ...I O connector pins on the bottom of the module Figure 2 SCC Module Bottom View Table 1 lists the signal connection corresponding to each pin GND is the reference for the 5 V supply 1 Pin 1 2 Pin 2 3 P...

Страница 8: ...high on the digital line Sensing DC Voltages The SCC DI01 registers a logic high when a positive or negative DC voltage of 2 V or more exists across the screw terminals If no voltage is present the S...

Страница 9: ...in your software the patents txt file on your CD or ni com patents 2002 2004 National Instruments Corp All rights reserved 371076B 01 Mar04 371076B 01 Isolating Signals The VIN and VCOM signals are is...

Отзывы: