Dynamic Response
Bandwidth (–3 dB) .................................10 kHz
Output settling time to within
0.01% of nominal input voltage .............15
µ
s
Output slew rate......................................0.75 V/
µ
s min
Power Requirement
Analog power .........................................100 mW max
+
15 V ...............................................3.2 mA max
–15 V ...............................................3.2 mA max
Digital power (
+
5 V) ..............................0.0 mA
Physical
Dimensions .............................................8.89 cm
×
2.92 cm
×
1.85 cm
(3.5 in.
×
1.15 in.
×
0.73 in.)
I/O connectors.........................................One 20-pin right-angle
male connector,
one 4-pin screw terminal
Wire gauge range....................................24 to 12 AWG
Maximum Working Voltage
Maximum working voltage refers to the signal voltage plus the
common-mode voltage.
Channel-to-earth .....................................100 V, Installation Category I
Channel-to-channel.................................100 V, Installation Category I
Environmental
Operating temperature ............................0 to 50 °C
Storage temperature ................................–20 to 70 °C
Humidity .................................................10 to 90% RH, noncondensing
Maximum altitude...................................2,000 m
Pollution Degree (indoor use only) ........2