2. In MAX, expand your system under Remote Systems and select 

Troubleshoot Remote

System Discovery

.

System Reset

The following figure shows the reset behavior of the sbRIO-9607.

Figure 3.

 Reset Button Behavior

Press and hold RESET button for 

 5 s

Press and hold RESET button for 

<

 5 s

Run Mode

Safe Mode

Press and hold RESET button for 

<

 5 s

Press and hold RESET button for 

 5 s

Press and hold 

RESET button for 

 5 s

Press and hold 

RESET button for 

<

 5 s

• Console Out enabled
• Network settings reset
• RT Startup App disabled
• FPGA Startup App disabled

• Console Out enabled
• RT Startup App disabled
• FPGA Startup App disabled

Safe Mode

STATUS LED Indicators

The following table lists the STATUS LED indicators.

8

  | 

ni.com

  | 

NI sbRIO-9607 Getting Started Guide

Содержание sbRIO-9607

Страница 1: ...sbRIO 9607...

Страница 2: ...Exercise caution when designing an enclosure for the sbRIO 9607 Auxiliary cooling may be necessary to keep the sbRIO 9607 within the specified operating temperature range Refer to the NI sbRIO 9607 S...

Страница 3: ...ies II III or IV Preparing the Environment Ensure that the environment in which you are using the sbRIO 9607 meets the following specifications Local ambient operating temperature near device IEC 6006...

Страница 4: ...ation from the kit Store the device in the antistatic package when the device is not in use Verifying the Kit Contents Verify that the following items are included in the sbRIO 9607 kit Figure 1 sbRIO...

Страница 5: ...nfo and enter the Info Code softwareversion Connecting the sbRIO 9607 The sbRIO 9607 has the following components Figure 2 sbRIO 9607 Components 1 2 3 4 5 6 7 8 12 11 15 13 10 10 11 14 16 9 9 1 J9 Pow...

Страница 6: ...til the connector latches into place 3 Turn on the power supply Powering On the NI sbRIO Device The NI sbRIO device runs a power on self test POST when you apply power to the device During the POST th...

Страница 7: ...O 9607 is admin There is no default password for the sbRIO 9607 so you must leave the password field blank when logging in until you set a system password 1 Right click your system and select Web Conf...

Страница 8: ...is complete Troubleshooting the sbRIO 9607 The sbRIO 9607 is Not Communicating with the Network Ensure that the Ethernet connections between the sbRIO 9607 and the host computer and the Ethernet conne...

Страница 9: ...on for 5 s Run Mode Safe Mode Press and hold RESET button for 5 s Press and hold RESET button for 5 s Press and hold RESET button for 5 s Press and hold RESET button for 5 s Console Out enabled Networ...

Страница 10: ...nto safe mode by pressing the reset button for longer than five seconds or by enabling safe mode in MAX Refer to the Measurement Automation Explorer MAX Help for information about safe mode Blinks fou...

Страница 11: ...orldwide Support and Services The National Instruments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application deve...

Страница 12: ...ited States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current e...

Страница 13: ...d third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance pol...

Отзывы: