National Instruments RMX-4120 Скачать руководство пользователя страница 14

14

|

ni.com

|

RMX Programmable Power Supplies Safety Information & Installation Guide

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

 you have 

access to everything from troubleshooting and application development self-help resources to 
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical 

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 
Communities using the manufacturer’s declaration of conformity. This system affords the user 
protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting 

ni.com/certification

. If your product supports calibration, 

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 
78759-3504. NI also has offices located around the world. For telephone support in the United 
States, create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). 

For telephone support outside the United States, visit the Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which provide up-to-date contact 

information, support phone numbers, email addresses, and current events.

Содержание RMX-4120

Страница 1: ...supplies Safety Guidelines Indicates general danger warning or caution When this symbol is marked on the product see the relevant section in the operation manual Indicates a location whose surface can...

Страница 2: ...2 4123 750 W Models Necessary Cable North America Extra Hard Usage Cord min 300 V 60 C 14 AWG 3 Conductor cord 3 m or less with a NEMA 5 15P to C14 Europe HAR Marked min 300 V 60 C 2 5mm2 3 Conductor...

Страница 3: ...e switchboard In an emergency turn off the switchboard breaker to disconnect the product from the AC power line Necessary Cable Vinyl cabtire cable VCTF Nominal cross sectional area 5 5 mm2 3 core Fin...

Страница 4: ...nal to the GND wire Figure 2 Attaching the Crimping Terminal 4 Connect the power cord and the included INPUT terminal cover to the AC INPUT terminal on the rear panel Be sure to connect the AC INPUT L...

Страница 5: ...ect Incorrect Incorrect The stripped wire is touching the chassis The wire strands are touching the chassis INPUT terminal cover INPUT terminal cover INPUT terminal cover AC INPUT terminal L Black or...

Страница 6: ...fied insulation voltage of the product to secure the double insulation or reinforced insulation Connecting to the Output Terminals Caution Risk of electric shock Turn the POWER switch off before you t...

Страница 7: ...re to the chassis terminal Use the screw on the output terminal to connect the wire to the output terminal Figure 5 RMX 4120 4121 4124 4125 Figure 6 RMX 4122 4123 4126 4127 3 Attach crimping terminals...

Страница 8: ...for RMX 4122 4123 4126 4127 Note If you do not connect load cables in the correct orientation you will not be able to attach the OUTPUT terminal cover Spring washer Washer Nut Bolt M8 Crimping termin...

Страница 9: ...bles that are between 10 mm and 18 mm in diameter Put the top and bottom halves of the OUTPUT terminal cover together so that the hole diameter is large 1 Remove the screw that is attached next to the...

Страница 10: ...ove Align the protrusion of the top half of the cover with the top section of the protrusion of the bottom half Bottom half of the cover For thick load cables Cover hole diameter 10 mm to 18 mm Cover...

Страница 11: ...category II Operating temperature 0 to 50 C 32 to 122 F Operating humidity 20 to 85 rh no condensation Altitude Up to 2 000 m Pollution degree 2 RMX 4124 4125 4126 4127 AC Input Nominal input rating 1...

Страница 12: ...ass A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Group 1 Class A emissions FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions Note In the United...

Страница 13: ...ible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental information refer to the Min...

Страница 14: ...th the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can o...

Страница 15: ...nts You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal exp...

Отзывы: