2-28
|
ni.com
Chapter 2
Installation and BIOS Setup
View SMBIOS Event Log
This section displays the contents of the SMBIOS Event Log.
IPMI
Use this feature to configure Intelligent Platform Management Interface (IPMI) settings.
BMC Firmware Revision
This item indicates the IPMI firmware revision used in your system.
IPMI Status (Baseboard Management Controller)
This item indicates the status of the IPMI firmware installed in your system.
System Event Log
Enabling/Disabling Options SEL Components
Select Enabled for all system event logging at bootup. The options are
Enabled
and
Disabled
.
Erasing Settings
Erase SEL
Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes,
On every reset to erase all system event logs upon each system reboot. Select No to keep all
system event logs after each system reboot. The options are
No, Yes
,
On next reset
, and
Yes
,
On
every reset.
When SEL is Full
This feature allows the user to decide what the BIOS should do when the system event log is
full. Select Erase Immediately to erase all events in the log when the system event log is full.
The options are
Do Nothing
and
Erase Immediately
.
Note
After making changes on a setting, be sure to reboot the system for the
changes to take effect.
BMC Network Configuration
BMC Network Configuration
*The BMC network information is only valid when the IPMI Function is enabled.*
IPMI LAN Selection
This item displays the IPMI LAN setting. The default setting is
Failover
.