background image

©

 National Instruments Corporation

7

Getting Started with R Series Intelligent DAQ

The +5V terminals on the I/O connector 5 V referenced to D GND. Use these terminals to 
power external circuitry. All NI 78

xx

R devices are equipped with a fuse to protect the supply from 

overcurrent conditions. Refer to the 

R Series Intelligent DAQ User Manual

, available at 

ni.com/

manuals

, for information about the device-specific fuses.

Connectivity Options

Accessing the signals on the I/O connectors requires at least one cable and one signal accessory. Table 
summarizes the National Instruments connectivity options available for use with the NI 78

xx

R device.

For detailed information about connecting I/O signals, refer to the 

NI R Series Intelligent DAQ User 

Manual

, available at 

ni.com/manuals

.

Table 1.  

R Series Connectivity Options

Cable

Connector 

Accessory

Description

SHC68-68-RMIO

*

(NI Recommended)

0

NI SCB-68

High-performance shielded cable wired 
specifically for signal connection from the 
RMIO connector

 to the NI SCB-68 terminal 

block to provide higher signal integrity and noise 
immunity.

SHC68-68-RDIO
(NI Recommended)

1, 2

NI SCB-68

High-performance shielded cable wired 
specifically for signal connection from the 
RDIO connector

 to the NI SCB-68 terminal 

block to provide higher signal integrity and noise 
immunity.

SH68-C68-S

0, 1, 2

NI SCB-68

Basic shielded cable for signal connection from 
the RMIO or RDIO connector to the NI SCB-68 
terminal block for noise reduction.

CAT 5 Ethernet 
crossover cable

*

For use with the NI PXI-78

xx

R running the 

LabVIEW Real-Time Module, if the real-time 
PXI system is not configured on a network. 
To connect the PXI system to a network port, use 
a standard CAT 5 10/100Base-T Ethernet cable.

*

 NI 783

x

R/784

x

R/785

x

R devices only.

 For a diagram of the twisted pairs in the SHC68-68-RMIO and SHC68-68-RDIO cables and the signals to which they 

correspond, go to 

ni.com/info

 and enter the info code 

rdrmio

.

Содержание R Series Intelligent DAQ PCI/PXI-783xR

Страница 1: ...omponents The following items are necessary to set up and use the NI PCI PXI 78xxR The following software packages LabVIEW LabVIEW FPGA Module NI RIO device drivers Optional LabVIEW Real Time Module R...

Страница 2: ...lable at ni com manuals In LabVIEW 8 0 or later you can also view the LabVIEW Manuals directory that contains these documents by selecting Start All Programs National Instruments LabVIEW LabVIEW Manua...

Страница 3: ...the Read Me First Safety and Radio Frequency Interference document packaged with your PXI chassis or device before removing equipment covers or connecting or disconnecting any signal wires 2 Remove t...

Страница 4: ...ace the computer cover if applicable 7 Plug in and power on the computer or PXI chassis To confirm that your device is recognized complete the following additional steps 1 Select Start All Programs Na...

Страница 5: ...ND DGND DGND 5V 5V DIO28 DIO31 DIO33 DIO35 DIO37 DIO39 DIO0 DIO2 DIO3 DIO5 DIO6 DIO7 DIO8 DIO1 DIO4 DIO9 DIO10 DIO11 DIO12 DIO13 DIO14 DIO15 DIO16 DIO17 DIO18 DIO19 DIO20 DIO21 DIO22 DIO23 DIO24 DIO25...

Страница 6: ...AI5 1 AIGND4 AI4 1 AI3 AIGND2 AI2 AI1 AIGND0 AI0 35 1 36 2 37 3 38 4 39 5 40 6 41 7 42 8 43 9 44 10 45 11 46 12 47 13 48 14 49 15 50 16 51 17 52 18 53 19 54 20 55 21 56 22 57 23 58 24 59 25 60 26 61...

Страница 7: ...SHC68 68 RMIO NI Recommended 0 NI SCB 68 High performance shielded cable wired specifically for signal connection from the RMIO connector to the NI SCB 68 terminal block to provide higher signal integ...

Страница 8: ...rojects designed to help you get started using your R Series device 4 Select Basic I O and then select Analog Input R Series lvproj 5 The Analog Input example project opens in the Project Explorer win...

Страница 9: ...e new target and click OK i In the Project Explorer window right click the original FPGA target and select Remove to delete it from the project j Save the project to a new directory by selecting File...

Страница 10: ...m the shortcut menu as shown in the following figure 2 In the Project Explorer window right click the FPGA target and select New FPGA I O 3 In the New FPGA I O dialog box expand Connector0 and select...

Страница 11: ...from the FPGA Interface palette between the Invoke method and the Read Write Control that already exists on the block diagram c Wire the FPGA VI Reference Out terminal of the Invoke Method node to the...

Страница 12: ...0 Where to Go From Here The following resources contain information for writing applications and taking measurements with R Series Intelligent DAQ devices LabVIEW FPGA documentation Getting Started wi...

Страница 13: ...To access the LabVIEW FPGA IPNet visit ni com ipnet Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to every...

Страница 14: ...Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appr...

Отзывы: