background image

5.

For each port, configure the port mode to either Direct or Tap, depending on whether you
want to participate fully in network communication as an endpoint (Direct) or monitor an
existing network connection (Tap). Refer to the 

Port Modes

 section for more information.

6.

For each port, configure the PHY state to either Master or Slave, depending on the
corresponding state of the PHY that you are connecting to. Refer to the 

Phy State 

section

for more information.

Note

 

Two PHYs that are physically connected must be configured to use

opposing PHY states. One PHY must be configured to be the master, and the
other PHY must be configured to be the slave.

7.

(PXIe-8523 only)

 For each port, configure the link speed to either 100 Mb/s or 1000

Mb/s. Refer to the 

Link Speed

 section for more information.

Note

 

Two ports that are configured as Tap partners must be configured with

matching link speeds.

8.

Self-test the hardware by selecting the item in the configuration tree and clicking 

Self-

Test

 in the MAX toolbar.

The MAX self-test performs a basic verification of hardware resources.

Connection Guidelines

Notice

 

Operate this product only with cables less than 15 m in length.

1.

Push a solid wire or ferrule directly into the terminal.

2.

When inserting a stranded wire without a ferrule, first open the terminal by pressing the
push button with a finger or the included screwdriver tool.

3.

Verify that all strands of a stranded wire are securely retained.

4.

Insulated ferrules are recommended for small-gauge stranded wire. Insulated ferrules (26
AWG x 8 mm) are included with this product.

Note

 

A ferrule crimping tool is not included with this product.

5.

Tighten the connector screw flanges to the torque specification in the 

PXIe-8522

Specifications

 or 

PXIe-8523 Specifications

 for the best shock and vibration performance.

The connector screw flanges ship in a non-torqued configuration for easy removal.

6.

When removing a wire, first open the terminal by pressing the push button with a finger
or the included screwdriver tool.

4

  | 

ni.com

  | 

PXIe-8522/8523 User Manual

Содержание PXIe-8522

Страница 1: ...ew 7 Direct Mode 8 Tap Mode 9 PHY State 10 Link Speed 11 Programming the Module 11 LED Functionality 11 Synchronization Methods 12 Local Time 12 Network Time 13 Host Time 13 PXI Triggers 13 Introducti...

Страница 2: ...r any bends or damage prior to installation Do not install a module if the backplane is damaged 4 Remove the black plastic covers from all the captive screws on the module front panel 5 Identify a sup...

Страница 3: ...sis Configuring the Module in MAX Note NI XNET software which includes hardware drivers can be installed before or after the module is installed Use Measurement Automation Explorer MAX to configure yo...

Страница 4: ...he item in the configuration tree and clicking Self Test in the MAX toolbar The MAX self test performs a basic verification of hardware resources Connection Guidelines Notice Operate this product only...

Страница 5: ...ACT STATUS Link Act LED Port Identification Status LED Pin 1 Pin 2 Pin 3 Tap Pairs Ports Table 1 PXIe 8522 Pinout Signal Descriptions Pin Number Signal Type Signal Direction Signal Description Signal...

Страница 6: ...n Number Signal Type Signal Direction Signal Description Signal Required 1 TRX_P Bi directional Transceiver plus Required 2 TRX_M Bi directional Transceiver minus Required 3 Shield Shield Optional Por...

Страница 7: ...er Application PXIe Controller XNET OS Stack Intel i210 XNET Monitor XNET Endpoint DUT 802 1AS Firmware MAC PHY Each port has three data paths XNET monitor XNET endpoint and OS stack All three data pa...

Страница 8: ...via the monitor path by a Tap pair will be identical on each port in the pair The IEEE 802 1AS protocol is implemented by the firmware running on the module and packet timestamps are taken near the de...

Страница 9: ...lows you to analyze all network traffic that is transmitted and received on the port s endpoint In Direct mode ports are directly connected and function as endpoints Ethernet frames received and trans...

Страница 10: ...tically set the port s Tap partner to Tap mode The module supports two Taps Ports 1 2 and Ports 3 4 using this mode All four ports can also be used simultaneously while one pair is in Tap mode and the...

Страница 11: ...eeded function listed below API Functionality NI XNET Monitor AVB endpoint IEEE 802 1AS synchronization Trigger synchronization Port configuration Operating System Network Stack Network sockets TCP IP...

Страница 12: ...r NI hardware products such as DAQ IMAQ and NI Motion Control The PXI synchronization bus consists of a flexible interconnect scheme for sharing timing and triggering signals in a system Local Time Th...

Страница 13: ...ich the NI XNET driver is running The host time can obtain time date information using a real time clock RTC or a network time protocol NTP server Although host time provides accurate date time inform...

Страница 14: ...nts EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy an...

Отзывы: