10. Connect an Ethernet cable to a GigE Vision camera, then connect the camera

to the PXIe-8246 front panel.

11. Power on the chassis.

Note

 The first time you start the development computer after

installing the hardware, allow several seconds for the drivers to load.

Confirming the Device is Recognized

To confirm that the device is properly installed and the hardware is recognized,

complete the following steps:

1. Select 

Start

 » 

All Programs

 » 

National Instruments

 » 

Measurement &

Automation Explorer

 to open Measurement & Automation Explorer (MAX).

2. Verify that the camera connected to the PXIe-8246 appears under 

My

System

 » 

Devices and Interfaces

 » 

NI-IMAQdx Devices

.

Front Panel

The following figure shows the PXIe-8246 front panel.

ni.com

8

PXIe-8246 Getting Started

Содержание PXIe-8246

Страница 1: ...PXIe 8246 Getting Started 2023 04 03...

Страница 2: ...on Software and Driver 5 Installing Vision Builder AI 5 Installing the Vision Development Module 6 Installing the PXIe 8246 6 Confirming the Device is Recognized 8 Front Panel 8 Configuring the PXIe 8...

Страница 3: ...for Automated Inspection NI Vision Development Module VDM Note Before you begin install and configure your chassis and controller 2020 National Instruments Corporation All rights reserved Refer to the...

Страница 4: ...ce if it appears damaged in any way 3 Unpack any other items and documentation from the kit Store the device in the antistatic package when the device is not in use PXIe 8246 Kit Contents The followin...

Страница 5: ...ision Development Module Programming library for developing machine vision and scientific imaging applications The NI Vision Development Module requires an application development environment LabVIEW...

Страница 6: ...ase Notes on the NI Vision Acquisition Software installation media for system requirements and installation instructions for the NI IMAQdx driver Documentation for the NI IMAQdx driver software is ava...

Страница 7: ...Express Hybrid Peripheral Slot 4 PXI Express System Timing Slot 5 PXI Express Peripheral Slot 6 Touch any metal part of the chassis to discharge static electricity 7 Place the module edges into the m...

Страница 8: ...e Device is Recognized To confirm that the device is properly installed and the hardware is recognized complete the following steps 1 Select Start All Programs National Instruments Measurement Automat...

Страница 9: ...corresponds to the port will be lit Table 1 PoE LED Status Definitions LED Status Definition Red PoE protection is triggered 1 Green PoE is operational Unlit PoE is off Table 2 Ethernet LED Status Def...

Страница 10: ...s all modules installed in the chassis Your default names may vary Note If you do not see your module listed press F5 to refresh the list of installed modules If the module is still not listed power o...

Страница 11: ...Devices also confirm that no error conditions appear for the PCI to PCI Bridge 2 If error conditions appear reinstall the NI Vision Acquisition Software VAS driver Where to Go Next Refer to the follow...

Страница 12: ...arn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures that...

Отзывы: