background image

1.

Touch the antistatic package to a metal part of the chassis before removing the device
from the package.

Caution

 

Never touch the exposed pins of connectors.

2.

Remove the device from the package and inspect the device for loose components or any
other sign of damage.

3.

Notify National Instruments if the device appears damaged in any way. Do 

not

 install a

damaged device into your chassis.

Electrical

Power Rail

Typical Value

Max Value

 

 

 

+3.3 VDC

0.64 A

0.96 A

+12 VDC

1.1 A

1.65 A

Total Power

15.31 W

22.97 W

Preparing the Environment

Ensure the environment you are using the PXIe-8240 in meets the following specifications.

Ambient temperature range

0 °C to 55 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2.)

Relative humidity range

10% to 90%, noncondensing (Tested in
accordance with IEC-60068-2-56.)

Maximum altitude

2,000 m (800 mbar)

Pollution Degree

2

Indoor use only.

Note

 

Refer to the 

PXIe-8240 User Manual

 for full PXIe-8240 specifications.

Hardware Installation

The following are general instructions for installing the PXIe-8240.
Complete the following steps to install the PXIe-8240 in your PXI Express chassis.
1.

Power off your PXI Express chassis, but leave it plugged in while installing the
PXIe-8240. The power cord grounds the chassis and protects it from electrical damage
while you install the module.

Caution

 

To protect both yourself and the chassis from electrical hazards,

leave the chassis off until you finish installing the PXIe-8240.

2.

Remove or open any doors or covers blocking access to the slot in which you intend to
install the PXIe-8240.

2

  | 

ni.com

  | 

PXIe-8240 Getting Started Guide

Отзывы: