background image

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For telephone support in the United
States, create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For

telephone support outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/

niglobal

 to access the branch office websites, which provide up-to-date contact information,

support phone numbers, email addresses, and current events.

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at 

ni.com/trademarks

 for

information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their
respective companies. For patents covering NI products/technology, refer to the appropriate location: 

Help

»

Patents in your

software, the 

patents.txt

 file on your media, or the National Instruments Patent Notice at 

ni.com/patents

. You can find

information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer
to the Export Compliance Information at 

ni.com/legal/export-compliance

 for the NI global trade compliance policy and how

to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS
TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.
Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2017 National Instruments. All rights reserved.

376806A-01

May17

Содержание PXIe-8238

Страница 1: ...limits for electromagnetic compatibility EMC stated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated...

Страница 2: ...C industry has improved the available bus bandwidth by evolving PCI to PCI Express PXI is now able to meet even more application needs by integrating PCI Express into the PXI standard By taking advant...

Страница 3: ...ch to a PXI Express system via a high bandwidth low latency PXI Express backplane Gen2 x8 link With the 10Gb Ethernet it allows offloading data from a PXI Express system to an external storage solutio...

Страница 4: ...ing user interfaces a complete ANSI C environment for building your test program logic and a collection of automated code generation tools as well as utilities for building automated test systems moni...

Страница 5: ...x and support for more than two hundred devices on Linux with the NI DAQmx driver you now can create Virtual Instruments based on the Linux OS The NI VISA driver for Linux has improved instrument cont...

Страница 6: ...6 02 mm 2 645 in 67 17 mm 2 296 in 58 32 mm 1 948 in 49 47 mm 0 000 in 0 00 mm 0 249 in 6 33 mm 0 612 in 15 54 mm NI PXIe 8238 ETH 0 LINK ACT LINK ACT SPEED SPEED ETH 1 Electrical Power Rail Typical V...

Страница 7: ...tal Operating Environment Ambient temperature range 0 C to 55 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 6...

Страница 8: ...of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions E...

Страница 9: ...ize Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not includ...

Страница 10: ...TD VeeT VeeR RS1 Rx_LOS RSO MOD_ABS SCL Tx_Disable SDA Tx_Fault VeeT 10 9 8 7 6 5 4 3 2 20 1 11 12 13 14 15 16 17 18 19 Table 1 SFP Connector Signals Pin Symbol Name Description 1 VeeT Module Transmit...

Страница 11: ...Receiver Ground 15 VccR Module Receiver 3 3 V Supply 16 VccT Module Transmitter 3 3 V Supply 17 VeeT Module Transmitter Ground 18 TD Transmitter Non Inverted Data Input 19 TD Transmitter Inverted Dat...

Страница 12: ...hone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers em...

Отзывы: