manualshive.com logo in svg
background image

4

|

ni.com

|

NI PXIe-4610 Power Amplifier Getting Started Guide

8.

Hold the injector/ejector handle down as you slowly slide the module into the chassis until 
the handle catches on the injector/ejector rail, as shown in Figure 1.

Figure 1.  

Sliding the NI PXIe-4610 into the Chassis

9.

Raise the injector/ejector handle to latch the module into the chassis. The front panel of the 
NI PXIe-4610 should be even with the front panel of the chassis.

10. Tighten the two front panel mounting screws to 0.31 N · m (2.7 lb · in.) on the top and 

bottom of the module front panel to secure the NI PXIe-4610 to the chassis.

11. Power on the chassis.

Configure the Hardware in MAX

Use Measurement & Automation Explorer (MAX) to configure your National Instruments 
hardware. MAX informs other programs about which devices reside in the system and how they 
are configured. MAX is automatically installed with NI-DAQmx.

1.

Launch MAX.

2.

In the Configuration pane, expand 

Devices and Interfaces

 to see a the list of installed 

devices. Installed devices appear under the name of their associated chassis.

3.

Expand your 

Chassis

 tree item.

Note

MAX lists all devices installed in the chassis. Your default device names may 

vary.

4.

Record the device identifier MAX assigns to the hardware. Use this identifier when 
programming the NI PXIe-4610.

1

PXI Express Chassis

2

NI PXIe-4610 Module

3

Injector/Ejector Handle in Down Position

2

3

1

Содержание PXIe-4610

Страница 1: ...d to a test object or if the product is used in residential areas To minimize the potential for the product to cause interference to radio and television reception or to experience unacceptable perfor...

Страница 2: ...device for loose components or any other sign of damage Notify NI if the device appears damaged in any way Do not install a damaged module into your system Store the module in the antistatic package w...

Страница 3: ...on 4 When installation completes select Restart in the dialog box that asks if you want to restart shut down or restart later Install the Hardware You must install the software before using the hardwa...

Страница 4: ...sis 11 Power on the chassis Configure the Hardware in MAX Use Measurement Automation Explorer MAX to configure your National Instruments hardware MAX informs other programs about which devices reside...

Страница 5: ...fied 10X option button for each channel you want to enable Connect a Signal Source to the NI PXIe 4610 Input You can connect ground referenced and floating signal sources to the NI PXIe 4610 inputs Re...

Страница 6: ...ground referenced You can connect floating loads and balanced ground referenced loads to the NI PXIe 4610 outputs Refer to Figure 8 for the NI PXIe 4610 front panel Note Refer to the NI PXIe 4610 Spec...

Страница 7: ...NI PXIe 4610 outputs Note Connecting an unbalanced ground referenced load to an NI PXIe 4610 output introduces an unbalanced ground loop that may degrade the dynamic performance of the amplifier Caut...

Страница 8: ...8 ni com NI PXIe 4610 Power Amplifier Getting Started Guide Figure 8 NI PXIe 4610 Front Panel...

Страница 9: ...with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You ca...

Страница 10: ...ruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents You can find...

Отзывы: