background image

PXIe-4162 Purpose and Introduction

This document explains how to install, configure, and test the PXIe-4162. The

PXIe-4162 ships with NI-DCPower driver software, which you can use to program the

module.

Note

 Before you begin, install and configure your chassis and controller.

Verifying the System Requirements

To use the NI-DCPower instrument driver, your system must meet certain

requirements.
Refer to the product readme, which is available on the driver software media or

online at 

ni.com/manuals

, for more information about minimum system

requirements, recommended system, and supported application development

environments (ADEs).

Unpacking the Kit

Notice

 To prevent electrostatic discharge (ESD) from damaging the

module, ground yourself using a grounding strap or by holding a grounded

object, such as your computer chassis.

1. Touch the antistatic package to a metal part of the computer chassis.
2. Remove the module from the package and inspect it for loose components or

other signs of damage.

Notice

 Never touch the exposed pins of connectors.

Note

 Do not install a module if it appears damaged in any way.

3. Unpack any other items and documentation from the kit.

© National Instruments

3

PXIe-4162

Содержание PXIe-4162

Страница 1: ...PXIe 4162 2022 07 06...

Страница 2: ...4162 6 PXIe 4162 Pinout and LEDs 7 Configuring the PXIe 4162 in MAX 12 Self Calibrating the PXIe 4162 13 Programming the PXIe 4162 14 Troubleshooting 15 What Should I Do if the PXIe 4162 Doesn t Appea...

Страница 3: ...for more information about minimum system requirements recommended system and supported application development environments ADEs Unpacking the Kit Notice To prevent electrostatic discharge ESD from d...

Страница 4: ...irements specified in this guide and chassis documentation Optional Items PXI Slot Blocker Kit NI part number 199198 01 SHDB62M DB62M LL Low Leakage Cable for SMU 62 D Sub Male to 62 D Sub Male 1 m NI...

Страница 5: ...del is intended for use in indoor applications only Related information http www ni com manuals 1 Not all chassis with slot cooling capacity 58 W can achieve this ambient temperature range Refer to PX...

Страница 6: ...e using the edges or the metal bracket 1 Ensure the AC power source is connected to the chassis before installing the PXIe 4162 The AC power cord grounds the chassis and protects it from electrical da...

Страница 7: ...e into the slot until it is fully inserted 10 Latch the module in place by pulling up on the ejector handle 11 Secure the module front panel to the chassis using the front panel mounting screws Note T...

Страница 8: ...tor pins channels and LEDs PXIe 4162 OUTPUT 12 CH Precision SMU ACCES S VOLTAGE ALL CHANNEL SIGNALS 24V MAX 60V MAX to A B Item A LED Access Status indicator B LED Voltage Status Indicator Status Indi...

Страница 9: ...H10 Sense HI CH10 Guard CH10 Output HI CH7 Guard CH7 Sense LO CH7 Output HI CH7 Sense HI CH0 to 11 Output LO CH4 Guard CH4 Sense LO CH4 Output HI CH4 Sense HI CH1 Sense LO CH1 Guard CH0 Output HI CH0...

Страница 10: ...5 4D31 A90A 3B6C1E4E3A23__GUARDTERMINALS B 3 57 Output HI 56 Sense HI 36 Sense LO 37 Guard GUID 0B3D8A7D C725 4D31 A90A 3B6C1E4E3A23__GUARDTERMINALS 4 15 Output HI 14 Sense HI 12 Sense LO 13 Guard GUI...

Страница 11: ...RMINALS D 9 46 Output HI 45 Sense HI 25 Sense LO 26 Guard GUID 0B3D8A7D C725 4D31 A90A 3B6C1E4E3A23__GUARDTERMINALS 10 4 Output HI 3 Sense HI 1 Sense LO 2 Guard GUID 0B3D8A7D C725 4D31 A90A 3B6C1E4E3A...

Страница 12: ...0 49 48 51 45 44 43 46 20 21 19 18 17 14 13 12 15 8 7 6 9 10 3 2 1 4 42 62 41 40 38 37 36 35 34 33 31 30 29 28 27 26 25 24 23 22 56 13 12 15 14 55 54 57 37 36 35 Sense LO Sense HI Sense HI Guard Outpu...

Страница 13: ...talled modules If the module is still not listed power off the system ensure the module is correctly installed and restart 4 Record the identifier MAX assigns to the hardware Use this identifier when...

Страница 14: ...tion Within 24 hours of the previous self calibration Related tasks What Should I Do if the PXIe 4162 Fails the Self Test Programming the PXIe 4162 You can generate signals interactively using Instrum...

Страница 15: ...Measurement I O NI DCPower Examples are available from the Start menu in the National Instruments folder The NI DCPower API configures and operates the module hardware and performs basic acquisition...

Страница 16: ...ion Windows 10 8 1 Right click the Start button and select Device Manager Windows 7 Select Start Control Panel Device Manager 5 Verify the PXIe 4162 appears in the Device Manager 1 Under an NI entry c...

Страница 17: ...he chassis Note If you are using a PC with a device for PXI remote control system power on the chassis before powering on the computer 6 Verify that the module appears in MAX 7 Reset the module in MAX...

Страница 18: ...le Finder EXPLORE LEARN CREATE DISCOVER Support ni com support Services ni com services PXIe 4162 Specifications NI Community ni com community Power Supplies Solutions ni com powersupplies Worldwide S...

Страница 19: ...866 ASK MYNI 275 6964 For support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information Na...

Отзывы: