background image

The backplane connects the system slot to a PCI Express switch using a Gen-3 x8 and a Gen-3
x16 PCI Express link. The PCIe switch is divided into 2 logical PCIe switches to distribute
PCIe connections to the peripheral slots and to 2 PCIe-to-PCI bridges to provide PCI busses to
the hybrid peripheral slots.

System slot link 1 is a Gen-3 x8 PCI Express link to the primary PCI Express switch,
providing a nominal bandwidth of 8 GB/s (single direction) between the system controller and
logical PCI Express switch 1. PXI Express peripheral slots 2-4 are connected to logical PCI
Express switch 1 with Gen-3 x8 PCI Express links and are downstream of system slot link 1.

System slot link 2 is a Gen-3 x16 PCI Express link to the primary PCI Express switch,
providing a nominal bandwidth of 16 GB/s (single direction) between the system controller
slot and logical PCI Express switch 2. PXI Express peripheral slots 5-9 are connected to
logical PCI Express switch 2 with Gen-3 x8 PCI Express links and are downstream of system
slot link 2.

The PCI Express-to-PCI bridges are connected to logical PCI Express switch 2 and provide a
32-bit, 33 MHz PCI bus for hybrid peripheral slots 2, 3, 4, 5, 7, 8, and 9.

The system controller slot also has connectivity to some PXI features such as: PXI_CLK10,
PXI Star, PXI Trigger Bus, and PXI Local Bus 6. By default, the system controller controls the
power supply with the PS_ON# signals. A logic low on this line powers on the power supply.

Note

 

The chassis Inhibit Mode must be set to Default mode for the system

controller to control the power supply.

Hybrid Peripheral Slots

The chassis provides seven (7) hybrid peripheral slots as defined by the

 PXI-5 PXI Express

Hardware Specification

: slots 2, 3, 4, 5, 7, 8, and 9. A hybrid peripheral slot can accept the

following peripheral modules:

A PXI Express peripheral with x8, x4, or x1 PCI Express link through a switch to the
system slot. Each PXI Express peripheral slot can link up to a Gen-3 x8 PCI Express,
providing a maximum nominal single-direction bandwidth of 8 GB/s.

A CompactPCI Express Type-2 Peripheral with x8, x4, or x1 PCI Express link to the
system slot or through a PCI Express switch to the system slot.

A hybrid-compatible PXI Peripheral module modified by replacing the J2 connector with
an XJ4 connector installed in the upper eight rows of J2. Refer to the 

PXI Express

Specification

 for details. The PXI peripheral communicates through the backplane’s 32-

bit PCI bus.

A CompactPCI 32-bit peripheral on the backplane’s 32-bit PCI bus.

The hybrid peripheral slots provide full PXI Express functionality and 32-bit PXI functionality
except for PXI Local Bus. The hybrid peripheral slot only connects to PXI Local Bus 6 left
and right.

PXIe-1092 User Guide

  | 

© National Instruments

  | 

7

Содержание PXIe-1092

Страница 1: ...heral Slots 7 System Timing Slot 8 Peripheral Expansion Slot 9 PXI Local Bus 10 PXI Trigger Bus 11 System Reference Clock 11 Installation and Configuration 12 Safety Information 13 Chassis Cooling Con...

Страница 2: ...ed Unpacking Carefully inspect the shipping container and the chassis for damage Check for visible damage to the metal work Check to make sure all handles hardware and switches are undamaged Inspect t...

Страница 3: ...d timing and synchronization features An optional timing and synchronization upgrade provides inter chassis trigger routing capability higher accuracy CLK10 and CLK100 connectors for 10 MHz reference...

Страница 4: ...ronization across multiple chassis Switchless CLK10 routing Optional Features Timing and synchronization upgrade Front and rear rack mount kits Replacement power supply EMC filler panels Slot blockers...

Страница 5: ...Express Hybrid Peripheral Slots 7x 6 PXI Express System Timing Slot 7 PXI Express System Controller Slot 8 Front Panel LEDs 9 Power Inhibit Switch 10 Chassis Carry Handle 11 DIP Switch Figure 2 Rear...

Страница 6: ...Instruments that can accommodate a variety of rack depths PXIe 1092 Backplane Overview Interoperability with CompactPCI The design of the PXIe 1092 provides you the flexibility to use the following d...

Страница 7: ...K10 PXI Star PXI Trigger Bus and PXI Local Bus 6 By default the system controller controls the power supply with the PS_ON signals A logic low on this line powers on the power supply Note The chassis...

Страница 8: ...I Express peripheral or hybrid peripheral slot can link up to a Gen 3 x8 PCI Express providing a maximum nominal single direction bandwidth of 8 GB s A PXI Express Peripheral with x8 x4 or x1 PCI Expr...

Страница 9: ...ipheral slots The peripheral expansion slot provides power and connectors for alignment but does not provide I O For more information about peripheral expansion slot connector pinouts refer to the Exp...

Страница 10: ...ND NC NC NC GND 3 GND 12 V 12 V GND GND GND GND 4 GND GND GND 3 3 V 3 3 V 3 3 V GND 5 GND NC NC NC GND NC GND 6 GND NC GND NC NC NC GND 7 GND NC NC NC GND NC GND 8 GND NC GND NC NC NC GND PXI Local Bu...

Страница 11: ...bridges through buffers This allows you to send trigger signals to and receive trigger signals from every slot in the chassis Static trigger routing user specified line and directional assignments can...

Страница 12: ...slot PXI_CLK10 PXIe_CLK100 and PXIe_SYNC100 have the default timing relationship described in the following figure Figure 6 System Reference Clock Default Behavior PXIe_CLK100 PXI_CLK10 PXIe_SYNC100...

Страница 13: ...nder such conditions this equipment is unsafe and may ignite the gases or gas fumes Part Replacement Only service this equipment with parts that are exact replacements both electrically and mechanical...

Страница 14: ...ces may result in undesired thermal related issues with the chassis or modules To aid in thermal health monitoring for either rack or benchtop use you can monitor the chassis intake temperatures in Me...

Страница 15: ...de Air Exhaust Vent Left Note The side exhaust vent not shown is located on the left side of the chassis Chassis Ambient Temperature Definition The chassis fan control system uses ambient intake air t...

Страница 16: ...tive mounting screws provided Installing Slot Blockers The cooling performance of the chassis can be improved by installing optional slot blockers Refer to the National Instruments website at ni com i...

Страница 17: ...If your power outlet does not have an appropriate ground connection you must connect the premise safety ground to the chassis grounding screw located on the rear panel To connect the safety ground com...

Страница 18: ...er manual for specific instructions and warnings Caution Be sure the chassis is connected to an AC power source before installing the system controller The AC power cord grounds the chassis and protec...

Страница 19: ...ller boots If the system controller does not boot refer to the Troubleshooting section or your system controller user manual Installing Peripheral Modules Caution The PXIe 1092 chassis has been design...

Страница 20: ...ctor Handle 2 PXI Peripheral Module 3 Peripheral Module Front Panel Mounting Screws 2x 4 PXIe 1092 Chassis 5 Injector Ejector Rail 6 When you begin to feel resistance push up on the injector ejector h...

Страница 21: ...n for the slot descriptions 6 Install the module in the chassis by aligning the module so that the right most portion of the multiple slot peripheral module will occupy the slot peripheral expansion s...

Страница 22: ...y Steady red The chassis power supply has failed Temperature LED Off Chassis is powered off Steady green Intake or exhaust temperature is within chassis operating range Steady red Intake or exhaust te...

Страница 23: ...tes Location Switch State Description 1 FAN Off Right Sets chassis Fan Mode to Auto On Left Sets chassis Fan Mode to High 2 PWR Off Right Sets chassis Inhibit Mode to Default On Left Sets chassis Inhi...

Страница 24: ...o mode for improved acoustic performance In High mode the speed of the chassis fans is fixed at high speed regardless of chassis intake air temperature Select High mode for maximum cooling performance...

Страница 25: ...ith your system controller PXI Platform Services creates the pxiesys ini and pxisys ini file which define your PXI system parameters Note The configuration steps for single or multiple chassis systems...

Страница 26: ...er program Dynamic reservation routing deallocation is on the fly within a user program based on National Instruments APIs such as NI DAQmx NI recommends dynamic reservations and routing are used when...

Страница 27: ...serve and route trigger lines for you so you won t have to route trigger lines manually Complete the following steps to configure trigger routings in MAX 1 In the Configuration tree select the chassis...

Страница 28: ...tation for the PXIe 1092 chassis is contained in the chassis ini file on the software media that comes with the chassis The information in this file is combined with information about the system contr...

Страница 29: ...odules Caution Always disconnect the power cable prior to servicing the chassis Interior Cleaning Use a dry low velocity stream of air to clean the interior of the chassis Use a soft bristle brush for...

Страница 30: ...the screw locations Using a Phillips screwdriver remove the screws Pull on the rear handle of the power supply to remove it from the back of the chassis C O O L IN G C L E A R A N C E S R E Q U IR E...

Страница 31: ...ear chassis feet 3 With the internal fan harness still connected carefully pull and rotate fan assembly from rear cavity of chassis Use caution when removing the fan assembly to avoid damaging the fan...

Страница 32: ...Module 2 5 3 4 1 1 Fan Harness Plug 2 PXI Express Chassis 3 PXI Module Fan Assembly 4 Rear Chassis Feet 2x 5 Mounting Screws 6x Figure 18 Internal Fan Harness 1 2 1 Fan Receptacle 2 Fan Harness Plug 3...

Страница 33: ...void damaging the internal wire harness 5 Pull side fan assembly straight from chassis and remove Installing the Side Fan Assembly Complete the following steps to install a new side fan assembly 1 Plu...

Страница 34: ...ppropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreeme...

Отзывы: