background image

Chapter 3

I/O Information

©

 National Instruments Corporation

3-7

NI PXI-8195/8196 User Manual

Parallel Port

Figure 3-6 shows the location and pinouts for the IEEE 1284 (parallel) 
connector on the NI PXI-8195/8196. Table 3-6 lists and describes the 
IEEE 1284 connector signals.

Parallel port adapter cables are available from National Instruments, 
part number 777169-01.

Figure 3-6.  

Parallel Port Connector Location and Pinout

Table 3-5.  

10/100/1000 LAN Connector LED States

LED

Color

LED State

Condition

Top

Green

Off

LAN link is not established.

On (steady state)

LAN link is established.

On (brighter and pulsing)

The controller is communicating with another 
computer on the LAN.

Bottom

Orange

Off

10 Mbit/sec data rate is selected.

On

100 Mbit/sec data rate is selected.

Green

On

1000 Mbit/sec data rate is selected.

Parallel Port

18

1

36

19

Содержание PXI-8196

Страница 1: ...PXI 8221 ...

Страница 2: ...PXI NI PXI 8195 8196 User Manual NI PXI 8195 8196 User Manual March 2005 371445A 01 ...

Страница 3: ...51190000 Israel 972 0 3 6393737 Italy 39 02 413091 Japan 81 3 5472 2970 Korea 82 02 3451 3400 Malaysia 603 9131 0918 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 351 210 311 210 Russia 7 095 783 68 51 Singapore 65 6226 5886 Slovenia 386 3 425 4200 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 5...

Страница 4: ...nts outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form electronic or mechanical including photocopying recording storing in an information retrieval system or translating in whole or in part without the prior written consent of National Instruments Corporation Trademarks National Instruments NI ni com and LabVIEW are trad...

Страница 5: ...nt of Communications DOC Changes or modifications not expressly approved by NI could void the user s authority to operate the equipment under the FCC Rules Class A Federal Communications Commission This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against ha...

Страница 6: ... Installing the NI PXI 8195 8196 2 1 How to Remove the Controller from the PXI Chassis 2 4 BIOS Setup 2 4 Entering BIOS Setup 2 4 Main Setup Menu 2 5 Advanced Setup Menu 2 6 PXI Setup Menu 2 8 LabVIEW RT Options Setup Menu 2 9 Boot Setup Menu 2 9 Exiting BIOS Setup 2 10 System CMOS 2 11 LabVIEW RT Configuration Switches 2 12 Drivers and Software 2 14 Files and Directories Installed on Your Hard Dr...

Страница 7: ...sCard 34 Slot 3 12 Front Panel Features 3 14 Data Storage 3 14 Chapter 4 Common Configuration Questions General Questions 4 1 Boot Options 4 1 Cables and Connections 4 2 Software Driver Installation 4 3 Chassis Configuration 4 4 Basic PXI System Configuration 4 5 Upgrade Information 4 6 PXI Configuration 4 8 Chapter 5 Troubleshooting Appendix A Specifications Appendix B Technical Support and Profe...

Страница 8: ...ou to pull down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to important information This icon denotes a caution which advises you of precautions to take to avoid injury data loss or a system crash bold Bold text denotes items that you must select or click in the software such as menu items and dialog box options Bo...

Страница 9: ...lpful as you read this manual PICMG 2 0 R3 0 CompactPCI Specification PCI Industrial Computers Manufacturers Group IEEE Standard P1284 1 1997 C MM Standard for Information Technology for Transport Independent Printer System Interface PCI Local Bus Specification Revision 2 2 PCI Special Interest Group PXI Hardware Specification Revision 2 1 PXI Systems Alliance PXI Software Specification Revision 2...

Страница 10: ...evels of environmental performance required by the vibration shock temperature and humidity extremes of industrial environments PXI adds mandatory environmental testing and active cooling to the CompactPCI mechanical specification to ease system integration and ensure multivendor interoperability Additionally PXI meets the more specific needs of instrumentation users by adding an integrated trigge...

Страница 11: ... 8196 has a 2 0 GHz processor all the standard I O and a 30 GB or larger hard drive It also has a PCI based GPIB controller and an ExpressCard 34 expansion slot Functional Overview This section contains functional descriptions of each major logic block on the NI PXI 8195 8196 embedded computer NI PXI 8195 8196 Functional Description The NI PXI 8195 8196 is a modular PC in a PXI 3U size form factor...

Страница 12: ... CPU is the socket definition for the Intel Pentium M processor families The SO DIMM block consists of two 64 bit DDR2 SDRAM sockets that can hold up to 1 GB each DUAL CH PXI Connector Flash ROM ATA 100 IDE Interface Chip Set Graphics Memory Controller Hub VGA Connector Socket 479 CPU Super I O COM 1 LPT 1 Chip Set I O Controller Hub PXI Triggers 4 Hi Speed USB 2 0 Connectors Gigabit Ethernet SMB ...

Страница 13: ...cts to either 10 Mbit 100 Mbit or 1 000 Mbit Ethernet interfaces The GPIB block contains the GPIB interface The ExpressCard 34 slot accommodates an ExpressCard 34 module National Instruments Software National Instruments has developed several software kits you can use with the NI PXI 8195 8196 NI DAQ has an extensive library of functions that you can call from your application programming environm...

Страница 14: ...isition boards After you have acquired raw data you can convert it into meaningful results using the powerful data analysis routines in LabVIEW LabVIEW also comes with hundreds of instrument drivers which dramatically reduce software development time because you do not have to spend time programming the low level control of each instrument Measurement Studio allows you to choose from standard envi...

Страница 15: ...g the NI PXI 8195 8196 The power cord grounds the chassis and protects it from electrical damage while you install the module Make sure the power switch is turned off Caution To protect both yourself and the chassis from electrical hazards leave the chassis powered off until you finish installing the NI PXI 8195 8196 module 2 Remove any filler panels blocking access to the system controller slot S...

Страница 16: ...t properly unless the handle is in its downward position so that it does not interfere with the injector rail on the chassis 6 Hold the handle as you slowly slide the module into the chassis until the handle catches on the injector ejector rail 7 Raise the injector ejector handle until the module firmly seats into the backplane receptacle connectors The front panel of the NI PXI 8195 8196 should b...

Страница 17: ...deo cable to the VGA connector 12 Connect devices to ports as required by your system configuration 13 Power on the chassis 14 Verify that the controller boots If the controller does not boot refer to the What if the NI PXI 8195 8196 does not boot section of Chapter 5 Troubleshooting Figure 2 2 shows an NI PXI 8196 installed in the system controller slot of a National Instruments PXI 1042 chassis ...

Страница 18: ...ships with default settings that work well for most configurations Caution Changing BIOS settings may lead to incorrect controller behavior and possibly an unbootable controller If this happens follow the instructions for restoring default settings in the System CMOS section In general do not change a setting unless you are absolutely certain what it does Entering BIOS Setup To start the BIOS setu...

Страница 19: ...to change this setting Use and in conjunction with Enter and Tab to change these values DMI Event Logging This setting brings up the DMI Event Logging submenu Refer to the DMI Event Logging Submenu section Require Keyboard to Boot When Yes a missing or malfunctioning keyboard causes the BIOS to halt with an error When No the BIOS allows booting without a keyboard If you are using a USB keyboard yo...

Страница 20: ...hether events are logged Disabling logging has no impact on system performance The default is Enabled Advanced Setup Menu This menu contains BIOS settings that normally do not require modification If you have specific problems such as unbootable disks or resource conflicts you may need to examine these settings Caution Changing settings in this menu may result in an unstable or unbootable controll...

Страница 21: ...is setting does not prevent boot sector modification by 32 bit operating system drivers that access the hard disk directly The default is No Integrated Peripherals Submenu Use this submenu to apply nondefault configurations to the front panel peripherals of an NI PXI 8195 8196 controller Normally you do not need to modify these settings as the factory default settings provide the most compatible a...

Страница 22: ...Not Supported INTS Routing You can route INTS to the controller s 21 frame serialized IRQ input for use by certain PXI carrier cards The default setting is Not Routed APIC Routing This item is valid only for Windows XP and 2000 and other modern operating systems Also a fresh install of the OS must occur for changes to the APIC Routing to take effect Select Enabled to initialize the IOAPIC and loca...

Страница 23: ...ects whether the controller should boot LabVIEW RT LabVIEW RT Safe Mode or an installed OS such as Windows XP The default is Use Hardware Switch Disable Startup VI If the controller becomes inaccessible because of a startup VI this switch can prevent VIs from automatically running at startup The default is Use Hardware Switch Reset IP Address If the controller is deployed to a different subnet fro...

Страница 24: ...xit Discarding Changes Any changes made to BIOS settings during this session of the BIOS setup program are discarded The setup program then exits and boots the controller without rebooting first Load Setup Defaults This setting restores all BIOS settings to the factory default This is useful if the controller exhibits unpredictable behavior due to an incorrect or inappropriate BIOS setting Notice ...

Страница 25: ...formation Complete the following steps to clear the CMOS contents 1 Power off the chassis 2 Remove the controller from the chassis 3 Move the jumper on W1 from pins 1 2 to pins 2 3 as shown in Figure 2 3 4 Wait one second Move the jumper back to pins 1 2 5 Reinstall the controller in the chassis Caution Do not leave the jumper on pins 2 3 Doing so decreases battery life Also the controller will no...

Страница 26: ...witches should remain in the OFF position The controller reads these switches only after a system reset You must reboot the controller for any changes to take place The NI PXI 8195 8196 controller includes the following LabVIEW RT configuration switches Switch 1 Boot LabVIEW RT Set this switch to ON to boot LabVIEW RT Switch 2 Boot Safe Mode Set this switch to ON to boot LabVIEW RT into safe mode ...

Страница 27: ...witch to ON to prevent VIs from automatically running at startup if the controller becomes inaccessible because of a startup VI Switch 4 Reset IP Address Set this switch to ON to reset the IP address to 0 0 0 0 and other TCP IP settings to their defaults Use this switch if moving the controller to a different subnet or if the current TCP IP settings are invalid Figure 2 4 shows the location of the...

Страница 28: ...sponding to each peripheral The os directory contains a subdirectory corresponding to the operating system installed on your computer The rest of the directories correspond to each peripheral in your system Within each of these directories are the drivers for the peripherals These files and directories are copied exactly from the manufacturer distribution disks so the naming conventions vary from ...

Страница 29: ...ach slot is supported but system performance will be slower than using two matched modules However two mismatched modules will result in better performance than using a single module National Instruments offers the following types of SO DIMMs for use with the NI PXI 8195 8196 controller 256 MB 32 MB 64 CL 4 1 18 in max 512 MB 64 MB 64 CL 4 1 18 in max 1 GB 128 MB 64 CL 4 1 18 in max Note National ...

Страница 30: ...ted area of your hard drive This protected area contains an image of the hard disk provided to you at the time of shipment Should you need to restore your software to its original condition you can access that image by pressing a hot key during the initial boot process For more information regarding these tools refer to the documentation on your hard drive in the c Images Firstware directory Note ...

Страница 31: ...I PXI 8195 8196 controllers include a preinstalled OS In some cases you may want to install a different OS When doing so consider the following guidelines Installing from a CD ROM The NI PXI 8195 8196 supports the installation of Windows XP from a USB CD ROM However many other operating systems do not support installation from a USB CD ROM For example Windows 2000 aborts during the install process...

Страница 32: ...8196 Models Video VGA 15 pin DSUB Intel Extreme Graphics controller All Serial COM1 9 pin DSUB 16550 RS 232 serial port All Ethernet LAN RJ45 10 100 1000 Ethernet connection All Parallel Parallel Port 36 pin champ IEEE 1284 All USB USB 4 pin Series A stacked receptacle USB 2 0 capable All PXI trigger Trigger SMB Routing PXI triggers to or from the backplane trigger bus All GPIB device GPIB 25 pin ...

Страница 33: ... Figure 3 2 shows the front panel layout and dimensions of the NI PXI 8195 Dimensions are in inches millimeters Figure 3 1 NI PXI 8196 Front Panel Layout and Dimensions 2 22 56 4 2 33 59 2 4 39 111 5 3 55 90 2 3 17 80 5 2 06 52 3 1 55 39 4 1 07 27 2 0 00 0 0 1 55 39 4 2 49 63 2 3 29 83 6 3 84 97 5 0 00 0 0 0 30 7 6 0 75 19 1 2 00 50 8 2 35 59 7 2 85 72 4 ...

Страница 34: ...the location and pinouts for the VGA connector on the NI PXI 8195 8196 Table 3 2 lists and describes the VGA connector signals AMP manufactures a mating connector with part numbers 748364 1 housing and 748333 2 pin contact 2 22 56 4 2 33 59 2 0 00 0 0 0 75 19 1 2 00 50 8 2 85 72 4 0 00 0 0 1 55 39 4 2 49 63 2 3 84 97 5 4 39 111 5 3 55 90 2 3 17 80 5 2 06 52 3 1 07 27 2 ...

Страница 35: ... Table 3 2 VGA Connector Signals Pin Signal Name Signal Description 1 R Red 2 G Green 3 B Blue 4 NC Not Connected 5 GND Ground 6 GND Ground 7 GND Ground 8 GND Ground 9 5V 5 V 10 GND Ground 11 NC Not Connected 12 SD Serial Data 13 HSync Horizontal Sync 14 VSync Vertical Sync 15 SC Serial Clock VGA 15 10 5 11 6 1 ...

Страница 36: ...ribes the COM1 connector signal AMP manufactures a serial port mating connector part number 745491 5 Figure 3 4 COM1 Connector Location and Pinout Table 3 3 COM1 Connector Signals Pin Signal Name Signal Description 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Ground 6 DSR Data Set Ready 7 RTS Ready to Send 8 CTS Clear to Send 9 RI Ring Indicator ...

Страница 37: ...ernet connector signals AMP manufactures a mating connector part number 554739 1 Figure 3 5 Ethernet Connector Location and Pinout Note The Ethernet controller can perform an automatic crossover thus eliminating the need for crossover cables Table 3 4 Ethernet Connector Signals Pin Fast Ethernet Gigabit Ethernet 1 TX TX_A 2 TX TX_A 3 RX RX_B 4 NC TX_C 5 NC TX_C 6 RX RX_B 7 NC RX_D 8 NC RX_D Ethern...

Страница 38: ...le from National Instruments part number 777169 01 Figure 3 6 Parallel Port Connector Location and Pinout Table 3 5 10 100 1000 LAN Connector LED States LED Color LED State Condition Top Green Off LAN link is not established On steady state LAN link is established On brighter and pulsing The controller is communicating with another computer on the LAN Bottom Orange Off 10 Mbit sec data rate is sel...

Страница 39: ...1 BUSY Device Busy 2 SLCT Select 3 ACK Acknowledge 4 FAULT ERROR Fault 5 PAPEREND Paper End 6 PD0 Data Bit 0 7 PD1 Data Bit 1 8 PD 2 Data Bit 2 9 PD3 Data Bit 3 10 PD4 Data Bit 4 11 PD5 Data Bit 5 12 PD6 Data Bit 6 13 PD7 Data Bit 7 14 INIT Initialize Printer 15 STROBE Strobe 16 SLCTIN Select Input 17 AUTOFD Auto Line Feed 18 5V 5 V 19 35 GND Ground 36 NC Not Connected ...

Страница 40: ...e Universal Serial Bus USB connector on the NI PXI 8195 8196 Table 3 7 lists and describes the USB connector signals AMP manufactures a USB mating connector part number 787633 Figure 3 7 USB Connector Location and Pinout Table 3 7 USB Connector Signals Pin Signal Name Signal Description 1 VCC Cable Power 5 V 2 Data USB Data 3 Data USB Data 4 GND Ground USB 4 1 ...

Страница 41: ...for routing PXI triggers to or from the backplane trigger bus Figure 3 8 shows the TRG connector location on the NI PXI 8195 8196 Table 3 8 lists and describes the trigger connector signals Figure 3 8 TRG Connector Location and Pinout Table 3 8 TRG Connector Signals Pin Signal Name Signal Description 1 TRIG Trigger 2 Shield GND Ground 1 2 ...

Страница 42: ... connector signals ITT Canon manufactures a GPIB mating connector part number MDSM 25SC Z11 V51 Figure 3 9 GPIB Connector Location and Pinout Table 3 9 GPIB Connector Signals Pin Signal Name Signal Description 1 DIO1 Data Bit 1 2 DIO2 Data Bit 2 3 DIO3 Data Bit 3 4 DIO4 Data Bit 4 5 EOI End or Identify 6 DAV Data Valid 7 NRFD Not Ready for Data 8 NDAC Not Data Accepted 9 IFC Interface Clear 10 SRQ...

Страница 43: ... the location and pinouts for the ExpressCard 34 slot on the NI PXI 8196 Table 3 10 lists and describes the ExpressCard connector signals Figure 3 10 ExpressCard 34 Slot Location and Pinout 11 ATN Attention 12 SHIELD Chassis ground 13 DIO5 Data Bit 5 14 DIO6 Data Bit 6 15 DIO7 Data Bit 7 16 DIO8 Data Bit 8 17 REN Remote Enable 18 25 GND Logic Ground Table 3 9 GPIB Connector Signals Continued Pin S...

Страница 44: ...d by spec for future use 6 RESERVED Reserved by spec for future use 7 SMBCLK SMBus Clock 8 SMBDATA SMBus Data 9 1 5V Power 10 1 5V Power 11 WAKE PE Wake 12 3 3VAUX Power 13 PERST PE Reset 14 3 3V Power 15 3 3V Power 16 CLKREQ Clock Request 17 CPPE PE Presence 18 REFCLK Reference Clock 19 REFCLK Reference Clock 20 GND Ground 21 PERn0 PE Data Receive 22 PERp0 PE Data Receive 23 GND Ground 24 PETn0 P...

Страница 45: ...dicate one of the following states ON steady PXI and onboard power is on and within regulation limits Blinking One of the PXI or onboard supplies is operating outside of the normal limits or is not functioning OFF The power to the controller is off The DRIVE LED indicates when an access to the internal hard disk is occurring Data Storage The NI PXI 8195 8196 has the following data storage features...

Страница 46: ...of the memory hard drive time date and so on You can view these parameters in the BIOS setup To enter the BIOS setup reboot the NI PXI 8195 8196 and press Delete during the memory tests Refer to the Entering BIOS Setup section of Chapter 2 Installation and Configuration for more information Can I use the internal IDE drive and an external SCSI hard drive at the same time Yes Boot Options What devi...

Страница 47: ...type You can set the boot order using and Set the order by device type and set the order for the devices listed within the device type To boot from a different device without permanently changing the boot order press Esc during POST After the BIOS completes the POST and just before the controller boots the OS the Boot menu is displayed You can select the device type you want to boot from Cables an...

Страница 48: ...the online catalog at ni com products Software Driver Installation How do I install or reinstall the video driver Refer to KnowledgeBase 3H3CO5D8 at ni com support How do I install or reinstall the Ethernet driver Refer to KnowledgeBase 3H3CO5D8 at ni com support How do I install or reinstall the GPIB driver The NI 488 2 driver for your GPIB port is installed by default when your controller is fir...

Страница 49: ...ndor to make sure Windows XP supports the drive Mapped network drive You can use the Ethernet to connect to another computer If you share the CD ROM drive on the other computer you can map the shared CD ROM drive to a drive letter on the NI PXI 8195 8196 Chassis Configuration How do I set up the NI PXI 8195 8196 to work with my chassis Configuration of the PXI system is handled through Measurement...

Страница 50: ...d Right click this entry to display the pop up menu then select the appropriate controller model from the Identify As submenu 4 Click the PXI System controller The chassis or multiple chassis in a multichassis configuration is listed below it Identify each chassis by right clicking its entry then selecting the appropriate chassis model through the Identify As submenu Further expanding the PXI Syst...

Страница 51: ...mation For detailed information about initialization files refer to the PXI specification at www pxisa org Upgrade Information How do I upgrade system memory You can change the amount of installed RAM on the NI PXI 8195 8196 by upgrading the DDR2 SO DIMM To upgrade the RAM remove the NI PXI 8195 8196 from the PXI chassis To optimize both memory capacity and system performance use the same size and...

Страница 52: ...he latest software drivers You can download the latest drivers from ni com support pxisupp htm My NI PXI 8195 8196 does not have an internal floppy drive Is there a way to use an external drive Yes The NI PXI 8195 8196 controller supports and can boot from USB floppy drives A USB floppy drive will not work with Windows NT4 but will work with Windows 2000 or Windows XP Refer to the Boot Options sec...

Страница 53: ...the PXI Features section of Chapter 2 Installation and Configuration Why doesn t the NI PXI 8195 8196 work with the PXI 8220 A serialized IRQ conflict with the PXI 8220 and the NI PXI 8195 8196 prevents PC cards using ISA interrupts from working with the NI PXI 8195 8196 controllers The PXI 8221 is designed to work with the NI PXI 8195 8196 and should be used instead ...

Страница 54: ...note the last screen output that you saw for reference when consulting National Instruments technical support What has changed about the system Did you recently move the system Was there electrical storm activity Did you recently add a new module memory chip or piece of software Things to Try Make sure the chassis is plugged in to a working power source Check any fuses or circuit breakers in the c...

Страница 55: ...iver may have defaulted to the CRT connector being disabled Press CTRL ALT F1 to re enable the CRT in Windows My system boots fine as long as a particular module is not in my chassis The most common cause of this is a damaged module Try the module in a different chassis or with a different controller Also remove any external cables or terminal blocks connected to the system If the module does not ...

Страница 56: ...t one second Move the jumper back to pins 1 2 5 Reinstall the controller in the chassis Caution Do not leave the jumper on pins 2 3 Doing so decreases battery life Also the controller will not boot Figure 5 1 Clearing the CMOS Contents 1 Normal Operation Default 2 Clear CMOS Contents 3 Pin 1 1 2 3 ...

Страница 57: ...l Physical Board dimensions PXI 3U size module 8 1 cm 13 cm 21 6 cm 3 2 in 5 1 in 8 5 in Slot requirements One system slot plus three controller expansion slots Compatibility Fully compatible with PXI specification Weight 0 77 Kg 1 7 lb typical Voltage V Current A Typical Maximum NI PXI 8195 NI PXI 8196 NI PXI 8195 NI PXI 8196 3 3 2 8 A 2 8 A 3 2 A 3 2 A 5 4 8 A 5 A 6 5 A 7 A 12 0 A 0 A 0 A 0 A 12...

Страница 58: ...t nonmetallic brush Make sure that the device is completely dry and free from contaminants before returning it to service Storage Environment NI PXI 8195 8196 Ambient temperature range 20 to 65 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 NI PXI 8196 Extended Temp Option Ambient temperature range 40 to 85 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity ...

Страница 59: ...ng standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CAN CSA C22 2 No 61010 1 Note For UL and other safety certifications refer to the product label or to ni com certification search by model number or product line and click the appropriate link in the Certification column Electromagnetic Compatibility Emissions EN 55011 Class...

Страница 60: ...ng as follows Low Voltage Directive safety 73 23 EEC Electromagnetic Compatibility Directive EMC 89 336 EEC Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column ...

Страница 61: ...l Instruments Application Engineers make sure every question receives an answer For information about other technical support options in your area visit ni com services or contact your local office at ni com contact Training and Certification Visit ni com training for self paced training eLearning virtual classrooms interactive CDs and Certification program information You also can register for in...

Страница 62: ...you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the front of this manual You also can visit the Worldwide Offices section of ni com niglobal to access the branch office Web sites which provide up to date contact information support phone numbers email addresses and current events ...

Страница 63: ... 8195 8196 User Manual Glossary Symbol Prefix Value n nano 10 9 µ micro 10 6 m milli 10 3 k kilo 103 M mega 106 G giga 109 T tera 1012 Symbols Degrees Ω Ohms Percent A A Amperes AC Alternating Current ASIC Application specific integrated circuit ...

Страница 64: ...y Metal Oxide Semiconductor A process used in making chips CompactPCI An adaptation of the PCI specification for industrial and or embedded applications that require a more robust mechanical form factor than desktop PCI CompactPCI provides a standard form factor for those applications requiring the high performance of PCI as well as the small size and ruggedness of a rack mount system D DC Direct ...

Страница 65: ...n and system boot functionality F FCC Federal Communications Commission G g 1 Grams 2 A measure of acceleration equal to 9 8 m s2 GPIB General Purpose Interface Bus IEEE 488 grms A measure of random vibration The root mean square of acceleration levels in a random vibration test profile H Hz Hertz Cycles per second I I O Input output The techniques media and devices used to achieve communication b...

Страница 66: ...pt signal ISA Industry Standard Architecture The original PC bus architecture specifically the 16 bit AT bus K KB Kilobytes of memory L LAN Local Area Network Communications network that serves users within a confined geographical area It is made up of servers workstations a network operating system and a communications link LED Light emitting diode M m Meters master A functional part of a PXI dev...

Страница 67: ...it or 64 bit bus with multiplexed address and data lines PCMCIA Personal Computer Memory Card International Association peripheral Any hardware device connected to a computer such as a monitor keyboard printer plotter disk or tape drive graphics tablet scanner mouse and so on POSC Power On Self Configuration PXI PCI eXtensions for Instrumentation An open implementation of CompactPCI that adds elec...

Страница 68: ... Seconds slave A functional part of a PXI device that detects data transfer cycles initiated by a PXI bus master and responds to the transfers when the address specifies one of the device s registers SO DIMM Small Outline Dual In line Memory Module SRAM Static RAM A memory chip that requires power to hold its content It does not require refresh circuitry as a dynamic RAM chip but it does take up m...

Страница 69: ...er installation 4 3 general questions 4 1 PXI configuration 4 8 upgrade information 4 6 CompactPCI specification 1 1 configuration common questions boot options 4 1 cables and connections 4 2 chassis configuration 4 4 driver installation 4 3 general questions 4 1 PXI configuration 4 8 upgrade information 4 6 connectors COM1 connector and signals 3 5 Ethernet connector and signals 3 6 ExpressCard 3...

Страница 70: ... 4 7 front panel connectors 3 1 dimensions 3 2 features 3 14 functional overview of NI PXI 8195 8196 1 2 G GPIB IEEE 488 2 3 11 connector location and pinout figure 3 11 connector signals table 3 11 3 13 driver installation 4 3 H hard drive 3 14 files and directories installed on 2 14 recovery 2 16 help technical support B 1 I IDE controller using SCSI hard drive in addition 4 1 IDE logic block 1 ...

Страница 71: ...ls 3 12 GPIB IEEE 488 2 connector and signals 3 11 parallel port connector and signals 3 7 trigger connector and signals 3 10 Universal Serial Bus USB connector and signals 3 9 VGA connector and signals table 3 4 data storage 3 14 front panel features 3 14 LEDs 4 1 system reset pushbutton 3 14 front panel dimensions 3 2 functional overview 1 2 hard drive recovery 2 16 installing DDR SO DIMMs figur...

Страница 72: ...fety specifications table A 3 serial port 3 1 See also COM1 connector shock and vibration specifications A 2 socket 479 1 CPU 1 3 SO DIMM logic block 1 3 software See also drivers installed on your hard drive 2 14 installing from CD ROM 4 4 LabVIEW 1 5 National Instruments software 1 4 NI DAQ 1 4 NI VISA 1 4 software NI resources B 1 specifications electrical A 1 electromagnetic compatibility A 3 ...

Страница 73: ...tor location and pinout figure 3 9 connector signals table 3 9 overview table 3 1 V VGA connector signals table 3 4 location and pinout figure 3 4 overview table 3 1 video 3 1 See also VGA driver installation 4 3 W Web resources B 1 Y Y splitter cable figure 4 2 using mouse and keyboard without 4 3 using with PS 2 mouse and keyboard 2 3 ...

Отзывы: