Appendix A
Specifications
PXI-8150 Series User Manual
A-4
©
National Instruments Corporation
Environmental
Note:
Random vibration profiles were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed
those recommended in MIL-STD-810E for Category 1 (Basic
Transportation, Figures 514.4-1 through 514.4-3). Test report
available upon request.
Adding RAM
To add RAM to the PXI-8150, remove the unit from the PXI mainframe
and add SO-DIMM modules to the empty SO-DIMM sockets. National
Instruments recommends the following types of SO-DIMMs for use
with the PXI-8150 Series controller (EDO):
16 MB:
2 MB
×
64 SO-DIMMs—60 ns
32 MB:
4 MB
×
64 SO-DIMMs—60 ns
64 MB:
8 MB
×
64 SO-DIMMs—60 ns
Note:
National Instruments has tested and verified that the SO-DIMMs we sell
work with the PXI-8150 Series. We recommend you purchase your
SO-DIMM modules from National Instruments. Other off-the-shelf
SO-DIMM modules are not guaranteed to work properly.
Characteristic
Specification
Temperature
0
°
to 50
°
C operating;
-20
°
to 70
°
C storage
Relative
Humidity
10% to 90% noncondensing, operating;
5% to 95% noncondensing, storage
EMI
FCC Class A verified, EC verified
Random
Vibration
Operational: 5 to 500 Hz, 0.31 g
RMS
, 3 axes
Non-operational: 10 to 500 Hz, 2.46 g
RMS
, 3 axes
Functional Shock
MIL-T-28800E Class 3 (per Section 4.5.5.4.1)
Half-sine shock pulse (11 ms duration, 30 g peak,
3 shocks per face). Also meets IEC standard
60068-2-27.