National Instruments PXI-7830R Скачать руководство пользователя страница 6

Getting Started with the NI 783xR

6

ni.com

Note 

The PCI-7831R supports NI-RIO 1.1 or later.

Computer running Windows 2000/XP and RTX.

Note 

RTX 5.5 does not support Hyper-Threading enabled processors. Refer to the RTX 

documentation for information about disabling multiprocessor access.

At least one cable and device for connecting signals to the PCI-783

x

R.

Installing Software

Complete the following sets of steps in the order listed to successfully 
install LabVIEW, the LabVIEW Real-Time Module, the LabVIEW FPGA 
Module, and the NI-RIO device drivers.

If you are using NI-RIO without LabVIEW, skip these steps and proceed to 
the 

NI-RIO Device Drivers Installation

 section.

LabVIEW Installation

Complete the following steps to install LabVIEW. Refer to the 

LabVIEW 

Release Notes

 for additional information about installing LabVIEW.

1.

Insert the LabVIEW CD into the CD-ROM drive to display the 
LabVIEW installation screen.

2.

Click 

Install LabVIEW

.

3.

Follow the installer prompts through the rest of the installation.

LabVIEW Real-Time Module Installation

Complete the following steps to install the LabVIEW Real-Time Module. 
Refer to the 

LabVIEW Real-Time Module Release Notes

 for additional 

information about installing the LabVIEW Real-Time Module.

Note 

If you are using the NI 783

x

R with Windows 2000/XP only, it is not necessary to 

install the LabVIEW Real-Time Module.

1.

Insert the LabVIEW Real-Time Module CD into the CD-ROM drive 
to display the LabVIEW Real-Time Module installation screen.

2.

Click 

Install LabVIEW Real-Time Module

.

3.

Follow the installer prompts through the rest of the installation.

Содержание PXI-7830R

Страница 1: ...to define device functionality and timing You can use the LabVIEW FPGA Module to graphically design the NI 783xR timing and functionality without having to learn a low level programming language or a...

Страница 2: ...How To Help Hardware and Software PXI 783xR with Windows 2000 XP The following items are necessary to set up and use the PXI 783xR on a computer running Windows 2000 XP NI PXI 783xR The following soft...

Страница 3: ...Module 1 0 or later and NI RIO 1 0 or later Host computer running Windows 2000 XP for developing your application PXI CompactPCI chassis and real time embedded controller running the Phar Lap ETS rea...

Страница 4: ...ystem to a network port use a standard CAT 5 10 100Base T Ethernet cable At least one cable and device for connecting signals to the PXI 783xR PCI 783xR with Windows 2000 XP The following items are ne...

Страница 5: ...Tool Suite ETS Note The PCI 7831R supports NI RIO 1 1 or later Host computer running Windows 2000 XP for developing your application Target computer running the Phar Lap ETS real time operating system...

Страница 6: ...the following steps to install LabVIEW Refer to the LabVIEW Release Notes for additional information about installing LabVIEW 1 Insert the LabVIEW CD into the CD ROM drive to display the LabVIEW inst...

Страница 7: ...ough the rest of the installation NI RIO Device Drivers Installation Complete the following steps to install the NI RIO device drivers that are included with the NI 783xR device Note You must install...

Страница 8: ...omponents or any other sign of damage Notify NI if the device appears damaged in any way Do not install a damaged device into the computer Store the NI 783xR in the antistatic envelope when not in use...

Страница 9: ...lug the computer Caution To protect both yourself and the computer from electrical hazards the computer must remain off and unplugged until the PCI 783xR is completely installed 2 Remove the computer...

Страница 10: ...Hardware tab and click Device Manager 8 For Windows XP expand NI RIO Devices right click the name of your device and select Update Driver In the Hardware Update Wizard window select Install the softw...

Страница 11: ...1 Close all NI software 2 Select Start Program Files Ardence RTX RTX RTX Properties 3 On the Plug and Play tab right click the name of your device and select Remove RTX INF Support 4 Click Apply RTX...

Страница 12: ...shows the I O connector locations for the NI PXI 783xR and the NI PCI 783xR The NI PXI 7830R and NI PCI 7830R do not have Connector 2 DIO Figure 1 NI 783xR Connector Locations CONNECTOR 0 MIO CONNECTO...

Страница 13: ...35 1 36 2 37 3 38 4 39 5 40 6 41 7 42 8 43 9 44 10 45 11 46 12 47 13 48 14 49 15 50 16 51 17 52 18 53 19 54 20 55 21 56 22 57 23 58 24 59 25 60 26 61 27 62 28 63 29 64 30 65 31 66 32 67 33 68 34 5V D...

Страница 14: ...s the electrical and mechanical aspects of the NI 783xR and contains information about its operation and programming Table 1 Cabling Options Cable Connector Description SH68 C68 S MIO DIO For connecti...

Страница 15: ...install the CompactRIO R Series Expansion chassis and CompactRIO I O modules Where to Go from Here Refer to the LabVIEW FPGA Module Release Notes for information about getting started with LabVIEW FPG...

Страница 16: ...l Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the ap...

Отзывы: