National Instruments PXI-5154 Скачать руководство пользователя страница 14

5.

Power on the chassis.

Note

 

If you are using a MXI controller, power on the chassis before powering

on the computer.

6.

Verify that the module appears in MAX.

7.

Reset the module in MAX and perform a self-test.

If the ACCESS LED still fails to light and failures continue, contact NI technical support or
visit 

ni.com/support

.

Related Information

Installing the PXI-5154

 on page 5

Installing the PCI-5154

 on page 6

What Should I Do if the PXI/PCI-5154 Doesn't Appear
in MAX?

1.

In the MAX configuration tree, expand 

Devices and Interfaces

.

2.

Expand the 

Chassis

 tree to see the list of installed hardware, and press <F5> to refresh

the list.

3.

If the module is still not listed, power off the system, ensure that all hardware is correctly
installed, and restart the system.

4.

Navigate to the Device Manager.

Operating System

Description

 

 

Windows 10/8.1

Right-click the Start button, and select 

Device Manager

.

Windows 7

Select 

Start

»

Control Panel

»

Device Manager

.

5.

If you are using a PXI or PXI Express controller, verify that a 

National Instruments

entry appears in the 

System Devices

 list. Reinstall NI-SCOPE and the module if error

conditions appear in the list. If you are using an MXI controller, right-click 

PCI-to-PCI

Bridge

, and select 

Properties

 from the shortcut menu to verify that the bridge is enabled.

What Should I Do if the Module Fails the Self-Test?

1.

Restart the system.

2.

Launch MAX, and perform the self-test again.

3.

Power off the chassis.

4.

Reinstall the failed module in a different slot.

5.

Power on the chassis.

6.

Perform the self-test again.

Thermal Shutdown Error

If you receive an over-temperature or thermal shutdown error and your device shuts down,
complete the following steps to re-enable your device:

14

  | 

ni.com

  | 

PXI/PCI-5154 Getting Started Guide

Содержание PXI-5154

Страница 1: ... manner not described in this document Contents Electromagnetic Compatibility Guidelines 2 Verifying the System Requirements 2 Unpacking the Kit 2 Kit Contents 3 Other Equipment 3 Preparing the Environment 4 PXI Modules 4 PCI Modules 4 Installing the Software 4 Installing the PXI 5154 5 Installing the PCI 5154 6 PXI PCI 5154 Front Panel Connectors and Indicators 8 Configuring the PXI PCI 5154 in M...

Страница 2: ...tion Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Verifying the System Requirements To use the PXI PCI 5154 your system must meet certain requirements For more information about minimum system requirements recommended system and supported application development envir...

Страница 3: ...al items not included in your kit to install or operate your device PXI Devices A PXI chassis a PXI SCXI combination chassis or a PXI CompactPCI chassis with a controller and the chassis documentation PCI Devices A desktop computer and its documentation Note If your application uses NI TClk synchronization for PCI devices you must use a RTSI cable to connect the PCI devices For more information re...

Страница 4: ...0068 2 1 and IEC 60068 2 2 Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Maximum altitude 2 000 m at 25 C ambient temperature Pollution Degree 2 Indoor use only Caution Clean the hardware with a soft nonmetallic brush Make sure that the hardware is completely dry and free from contaminants before returning it to service For complete specifications refer to...

Страница 5: ... slot pins on the chassis backplane for any bends or damage prior to installation Do not install a module if the backplane is damaged 4 Remove the black plastic covers from all the captive screws on the module front panel 5 Identify a supported slot in the chassis The following figure shows the symbols that indicate the slot types Figure 2 Chassis Compatibility Symbols NI PXIe 1062Q 1 2 3 4 5 1 PX...

Страница 6: ...ximize cooling air flow depending on your application 12 Power on the chassis Note For more information about maximizing cooling air flow refer to the Maintain Forced Air Cooling Note to Users included in your kit Related Information Why Is the ACCESS LED Off When the Chassis Is On on page 13 Installing the PCI 5154 1 Power off and unplug the computer 2 Access the computer system expansion slots T...

Страница 7: ...manufacturers use a securing lever made of plastic to secure PCI devices such a lever is unacceptable and must be removed Use the screw provided in the kit to screw down the device Otherwise you must use a different computer chassis 8 Replace any access panels on the computer case 9 Power on your computer 10 Verify that spread spectrum clocking is enabled in the PC BIOS For information about how t...

Страница 8: ... CH 0 CH 1 TRIG PFI 1 PFI 0 ACCESS ACTIVE CH0 CH1 TRIG PFI0 PFI1 Table 1 PXI PCI 5154 Front Panel Signal Connections Connector Description Function CH 0 CH 1 Standard BNC female connector Analog input connection digitizes data and triggers acquisitions TRIG Standard BNC female connector External analog trigger connection signals on the TRIG connector cannot be digitized 8 ni com PXI PCI 5154 Getti...

Страница 9: ...OPE 1 Launch MAX 2 In the configuration tree expand Devices and Interfaces to see the list of installed NI hardware Installed modules appear under the name of their associated chassis 3 Expand your Chassis tree item MAX lists all modules installed in the chassis Your default names may vary Note If you do not see your module listed press F5 to refresh the list of installed modules If the module is ...

Страница 10: ...alibration capabilities which you can access programmatically with NI SCOPE and your ADE or interactively with NI SCOPE SFP or MAX Related Information Making a Measurement on page 12 What Should I Do if the Module Fails the Self Test on page 14 What Should I Do if the PXI PCI 5154 Doesn t Appear in MAX on page 14 Programming the PXI PCI 5154 You can acquire data interactively using the NI SCOPE SF...

Страница 11: ...e Microsoft Visual C C Use examples located in the file directory Users Public Documents National Instruments NI SCOPE examples You can modify an NI SCOPE C example to create an application with Microsoft Visual C C Copy an NI SCOPE example to copy required project settings for include paths and library files Alternatively refer to the Creating an Application with Microsoft Visual C and C topic of...

Страница 12: ...the acquisition display 5 If the SFP is not already running click Run Making a Measurement with LabVIEW 1 Launch LabVIEW 2 Select Help Find Examples 3 Open the example VI that you want to use by selecting Hardware Input and Output Modular Instruments NI SCOPE High Speed Digitizers Tip If you are not sure which example to run use the Quick Start VI which is found under Hardware Input and Output Mod...

Страница 13: ... to NI RTSI Cable and select the device you want to add For more information about connecting PCI devices refer to NI High Speed Digitizers Help Programming Reference NI TClk Synchronization Help Troubleshooting Why Is the ACCESS LED Off When the Chassis Is On The LEDs may not light until the device has been configured in MAX Before proceeding verify that the PXI 5154 appears in MAX If the ACCESS ...

Страница 14: ...he Device Manager Operating System Description Windows 10 8 1 Right click the Start button and select Device Manager Windows 7 Select Start Control Panel Device Manager 5 If you are using a PXI or PXI Express controller verify that a National Instruments entry appears in the System Devices list Reinstall NI SCOPE and the module if error conditions appear in the list If you are using an MXI control...

Страница 15: ...6 Where to Go Next NI PXIe 4112 EXPLORE LEARN CREATE DISCOVER Located online at ni com manuals the application development environment ADE for your application about hardware features or review device specifications custom applications with an application programming interface API NI PXI PCI 5154 Specifications NI High Speed Digitizers Help NI SCOPE Soft Front Panel NI SCOPE Instrument Driver NI H...

Страница 16: ...phone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events Information is subject to change without notice Refer to the NI Trademarks and Logo Guidelines at ni com trademarks for information on NI trademarks Other product and...

Отзывы: