Installing NI-DCPower

NI-DCPower features a set of operations and attributes you can use to 
programmatically configure and control the NI DC power supply. Install 
or upgrade NI-DCPower 

before

 installing new hardware so Windows can 

detect your device. To install NI-DCPower, complete the following steps:

1. Insert the NI-DCPower CD. The NI-DCPower installer should open 

automatically. If not, select 

Start»Run

, and enter 

x

:\setup.exe

where 

x

 is the letter of the CD drive.

2. Follow the instructions in the installation prompts. For troubleshooting 

and operating system-specific instructions, refer to the Hardware 
Installation/Configuration Troubleshooter at 

ni.com/support/

install

.

Windows Vista 

Users may see access and security messages during 

installation. Accept the prompts to complete the installation. 

3. When the installer completes, a dialog box appears that asks if you want 

to restart, shut down, or restart later. Select 

Restart

.

4. If you are using a system running the LabVIEW Real-Time Module, 

download NI-DCPower to the target using MAX. Refer to the 

Measurement & Automation Explorer Remote Systems Help

 by selecting 

Help»Help Topics»Remote Systems

 in MAX.

Note

If you install NI application software after installing 

NI-DCPower, you must run the NI-DCPower installer again to 
install the correct application software support.

5. Installing the Hardware

Note

Make sure you install the software 

before

 you install the 

hardware.

Caution

To prevent damage due to ESD or contamination, handle 

the NI PXI-4110 using the metal bracket or edges. Refer to the 

Read 

Me First

Safety and Radio-Frequency Interference 

document for 

more information.

Содержание PXI-4110

Страница 1: ...rmation Current specifications are available at ni com manuals Visit ni com idnet for the latest version of NI DCPower instrument driver software Contents Conventions 2 1 Verifying the System Requirem...

Страница 2: ...erference document that shipped with your device for precautions to take When symbol is marked on a product it denotes a component that may be hot Touching this component may result in bodily injury b...

Страница 3: ...Power CD Note After you install NI DCPower you can access the NI DCPower Readme at Start All Programs National Instruments NI DCPower Documentation 2 Unpacking The NI DC power supply ships in an antis...

Страница 4: ...lies Getting Started Guide Other printed documents included in the kit NI PXI 4110 Specifications Read Me First Safety and Radio Frequency Interference Maintain Forced Air Cooling Note to Users 1 8 in...

Страница 5: ...indows Vista Users may see access and security messages during installation Accept the prompts to complete the installation 3 When the installer completes a dialog box appears that asks if you want to...

Страница 6: ...es or damage to the chassis and module 1 Power off and unplug the PXI chassis 2 Slide the NI PXI 4110 into an available slot until the ejector handle locks in the up position 3 Tighten the captive scr...

Страница 7: ...l does not appear repeat the steps in the 5 Installing the Hardware section Refer to NI Technical Support at ni com support for troubleshooting information if the module is still not recognized For mo...

Страница 8: ...e hazard or damage to the devices connected to the NI PXI 4110 NI is not liable for any damage or injuries resulting from incorrect signal connections The NI PXI 4110 has two connectors on the front p...

Страница 9: ...C Power Supplies Getting Started Guide Figure 2 NI PXI 4110 Front Panel T 6 3A L 250V 5 20 mm 11 15 5 VDC 5A MAX AUX POWER INPUT OUTPUTS 1A MAX 20 6 20 2 0 1 VDC MAX OUTPUT NI PXI 4110 Programmable DC...

Страница 10: ...utput Connector Terminal 3 Common Floating GND E Output Connector Terminal 4 Common Floating GND F Output Connector Terminal 5 Channel 2 0 V to 20 V G Auxiliary Power Input Connector Terminal 0 Auxili...

Страница 11: ...ply on the PXI chassis outputs the full voltage range but only a limited current range Note Connecting an auxiliary power source does not affect the 0 V to 6 V channel NI DCPower automatically uses th...

Страница 12: ...driver features a set of functions and attributes that exercise all the functionality of the NI PXI 4110 including configuration control and other device specific functions Refer to the NI DC Power Su...

Страница 13: ...so has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions...

Страница 14: ...National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer t...

Отзывы: